Dimensions LA 55-TP (in mm. 1 mm = 0.0394 inch)
Bottom view
Left view
Secondary terminals
Terminal + : supply voltage + 12 .. 15 V
Terminal - : supply voltage - 12 .. 15 V
Terminal M : measure
Connection
Standard 00
or N° SP..
Front view
Year Week
Mechanical characteristics
Remarks
•General tolerance
•Fastening & connection of primary
Recommended PCB hole
•Fastening & connection of secondary
Recommended PCB hole
± 0.2 mm
bus bar
6.4 x 1.6 mm
3.8 mm
3 pins
0.63 x 0.56 mm
0.9 mm
•IS is positive when IP flows in the direction of the arrow.
•Temperature of the primary conductor should not exceed
90°C.
•This is a standard model. For different versions (supply
voltages, turns ratios, unidirectional measurements...),
please contact us.
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without previous notice.