DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LA7565E View Datasheet(PDF) - SANYO -> Panasonic

Part Name
Description
Manufacturer
LA7565E Datasheet PDF : 18 Pages
First Prev 11 12 13 14 15 16 17 18
LA7565E, 7565KM
Coil Specifications
JAPAN
f = 58.75 MHz
VCO coil
S
t=5t
0.12 ø
C = 24 pF
A12072
Test production no. V291XCS-3220Z
Toko Co., Ltd.
US
f = 45.75 MHz
S
t=6t
0.12 ø
C = 24 pF
A12073
Test production no. 291XCS-3188Z
Toko Co., Ltd.
SAW filter (SPLIT)
Picture
TSF1137U
Sound
Picture
TSF1241
Sound
PAL
f = 38.9 MHz
S
t=7t
0.12 ø
C = 24 pF
A12074
Test production no. 292GCS-7538Z
Toko Co., Ltd.
Picture
TSF5315
Sound
SAW filter (INTER)
TSF5220
TSF5221
TSF5321
TSF5344
Toko Co., Ltd.
2-1-17 Higashi-yukigaya, Ohta-ku, Tokyo, Japan TEL: +81-3-3727-1167
Notes on VCO Tank Circuits
1. Built-in capacitor VCO tank circuits
When the power is turned on, the heat generated by the IC is transmitted through the printed circuit board to the VCO
transformer. At this point, the VCO coil frame functions as a heat sink and the IC heat is dissipated. As a result, it
becomes more difficult to transmit heat to the VCO transformer's built-in capacitor, and the influence of drift at
power on is reduced. Therefore, it suffices to design the circuit so that the coil and capacitor thermal characteristics
cancel. Ideally, it is better to use a coil with a core material that has low temperature coefficient characteristics.
2. External capacitor VCO tank circuits
When an external capacitor is used, heat generated by the IC is transmitted through the printed circuit board directly
to the VCO tank circuit external capacitor. While this capacitor is heated relatively early after the power is turned on,
the coil is not influenced as much by this heat, and as a result the power-on drift is increased. Accordingly, a coil
whose core material has low temperature coefficient characteristics must be used. It is also desirable to use a
capacitor with similarly low temperature coefficient characteristics.
Note: Applications that use an external capacitor here must use a chip capacitor. If an ordinary capacitor is used,
problems such as the oscillator frequency changing with the capacitor orientation may occur.
No. 6100-17/18

Share Link: 