LC72709E, 72709W
Continued from preceding page.
definition, the protection counts for both the forward and backward directions will be set to 1. However, from an
operation standpoint, this corresponds to operation equivalent to there being no protection circuit. The default values are
a forward protection count of 8 and a backward protection count of 2. We recommend resetting the block synchronization
backward protection count to a value stricter than the default, e.g. to a value of 3 or more as opposed to the default of 2, if
the block synchronization recognition output (the BLOCK pin, pin 23) is used to recognize the presence or absence of
FM multiplex data.
• Frame Synchronization Error Protection Count
This IC detects the four unique BIC inflection points that exist in a single frame, and increments or decrements the
protection counter depending on whether or not the IC internal frame synchronization counter matches. The data values
are set in the same way as those for the block synchronization protection count are set, namely data in which 1 has been
subtracted from the desired protection count must be transferred. The frame synchronization default values are 8 for
forward protection and 2 for backward protection.
• Control Registers
These registers are used to set the IC operating mode. These are described later.
• Notes
— The address bits DI12 to DI15 are ignored.
— Addresses other than those listed above (for example location 0110) are special addresses used for test mode and
other special IC functions. Do not set these locations.
— The default values are the values reloaded into the internal registers when a reset signal (RST) is received. These
values are the recommended values for normal operation, and normally do not need to be modified. If only the
default values are used, there is no need to provide data transfer routines in the external CPU.
Received data
Synchronization
counter BIC position
Block
: Both forward and backward protection counts are 3.
Figure 1 Block Synchronization Protection Operation
(forward backward forward)
Layer 4 CRC Check Circuit
This is a function provided for data group error detection, i.e. layer 4 CRC. After the stipulated number of bytes of data
group data and a 16-bit CRC error check word are transferred, the CRC4 pin outputs a high level if there were no errors.
The CRC4 pin outputs a high level if all the bits in the IC internal CRC check register were 0. When using this function
to perform the layer 4 CRC check, the IC internal CRC check register must be initialized before a single data group data
unit is transferred. This register is initialized by sending bit 7 of the control register. Note that since this flag is not
automatically reset to 0, the application must return it to 0 before transferring layer 4 CRC check data. If there were no
errors in any of the received data groups, the CRC register will always be all zeros after the CRC check of a single data
group. Therefore, the above control register initialization will not be necessary as long as there are no errors in the layer 4
CRC. The data length of the transferred data group data is in unit of 8 bits. Also note that while there is no upper limit on
the amount of data transferred in a single operation, data transfers can also be divided into multiple transfer operations.
No. 5876-7/16