LC74775, 74775M
Display Control Commands
Display control commands have an 8-bit format and are transferred using the serial input function. Commands consist of a
command identification code in the first byte and command data in the following bytes. The following commands are supported.
COMMAND0: Display memory (VRAM) write address setup command
COMMAND1: Display character data write command
COMMAND2: Vertical display start position and vertical character size setup command
COMMAND3: Horizontal display start position and horizontal character size setup command
COMMAND4: Display control setup command
COMMAND5: Display control setup command
COMMAND6: Synchronizing signal detection setup command
COMMAND7 to COMMAND12 and COMMAND18: Display control setup commands
COMMAND13 to COMMAND17: VPS/PDC control commands. These commands can only be written with the I2C bus
(the SCL and SDA pins).
Display Control Command Table
First byte
Second byte
Command
Command identification code
Data
Data
7
654
32 10 7 65
4
32 10
COMMAND0
(Write address setup)
1
0 0 0 V3 V2 V1 V0 0 0 0 H4 H3 H2 H1 H0
COMMAND1
(Character write)
1
001
0 0 0 0 at c6 c5 c4 c3 c2 c1 c0
COMMAND2 (Vertical character size and
vertical display start position)
1
0 1 0 VS VS VS VS 0 FS VP VP VP VP VP VP
21 20 11 10
5
4
32
1
0
COMMAND3 (Horizontal character size and 1
horizontal display start position)
0 1 1 HS HS HS HS 0 LC HP HP HP HP HP HP
21 20 11 10
5
4
32
1
0
COMMAND4
(Display control)
1
1 0 0 TST RAM OSC SYS 0 BLK BLK BLK BK BK RV DSP
MOD ERS STP RST
21
0
10
ON
COMMAND5
(Display control)
1
1 0 1 NP NP NON INT 0 RSH HLF BCL CB PH PH PH
10
LV2 INT
2 10
COMMAND6
(Synchronizing signal detection)
1
1 1 0 SEL MOD DIS MUT 0 RN RN RN SN SN SN SN
0 0 LIN
21
0
32
1
0
COMMAND7
(Display control)
1
111
0 0 0 0 0 CIN CIN VNP VSP MSK MSK EGL
SEL CTL SEL SEL ERS SEL
COMMAND8
(Display control)
1
111
0 0 0 1 0 LNA LNA LNA LNA LPA LPA LPA
32
1
02
1
0
COMMAND9
(Display control)
1
111
0 0 1 0 0 LNB LNB LNB LNB LPB LPB LPB
32
1
02
1
0
COMMAND10
(Display control)
1
111
0 0 1 1 0 LNC LNC LNC LNC LPC LPC LPC
32
1
02
1
0
COMMAND11
(Display control)
1
111
0 1 0 0 0 0 VSP VSP LNC MOD LNB MOD
DCK SLC SEL 3 SEL 2
COMMAND12
(Display control)
1
111
0 1 0 1 0 0 OTD OTD HLF SEL OTH IND
S1 S0 INT 2
COMMAND18
(Display control)
1
111
1 0 1 1 0 0 RNE SJN SJN SJN SJC SJC
0
3
21
1
0
COMMAND13
(VPS/PDC control)
1
111
0 1 0 1 0 CPA CPA CPA VPM VPM VPM VPM
21
0
32
1
0
COMMAND14
(VPS/PDC control)
1
111
0 1 1 0 0 VMW VMW HBS HBS BMS EMS DCE
SE2 SEL 2
1
COMMAND15
(VPS/PDC control)
1
111
0 1 1 1 0 0 ECV ECV ECV ECV ECV ECV
15 14 13 12 11 5
COMMAND16
(VPS/PDC control)
1
111
1 0 0 0 0 ECP ECP ECP ECP ECP ECP ECP
19 18 17 16 15 14 13
COMMAND17
(VPS/PDC control)
1
111
1 0 0 1 0 0 ECP ECP ECP ECP ECP ECP
25 24 23 22 21 20
Once written, a first byte command identification code is stored until the next first byte is written. However, when the
display character data write command (COMMAND1) is written, the LC74775/M locks into the display character data
write mode, and another first byte cannot be written.
When the CS pin is set high, the LC74775/M is set to the COMMAND0 (display memory write address setup mode) state.
No. 5919-9/35