LHFOSCH3
6.2.4 AC CHARACTERISTICS - READ-ONLY OPERATIONS(‘)
Vc,=2.7V-3.6V, TpO”C to +70X
Versiond4)
LH28F008SGL170
Sym. 1
Parameter
1Read Cycle Time
1 Notes
Min.
170
Max.
Unit
ns
See 5.OV V,, Read-Only Operations for notes 1 through 4.
Vc,=3.3V&0.3V, T ,=O”C to +70X
Sym. 1
Versiond4)
Parameter
1 LH28FOOSSGL150
1 Notes ( Min.
Max.
Unit
t*“n”
Read Cycle Time
150
ns
tA”n”
Address to Output Delay
150
ns
fF, 0” CE# to Output Delay
2
150
ns
tpH()” RP# High to Output Delay
600
ns
tr, 0"
OE# to Output Delay
2
55
ns
hny
CE# to Output in Low Z
3
0
ns
t&jQ7
CE# High to Output in High Z
3
55
ns
tr,, nx
OE# to Output : in Low Z
3
0
ns
tncln7 OE# High to Output in High Z
3
25
ns
bH
Output Hold from Address, CE# or OE# Change,
Whichever Occurs First
3
0
ns
NOTE:
See 5.OV V,, Read-Only Operations for notes 1 through 4.
Rev. 1.0