[Note ] Data Mapping
RXCLKIN-+/-
1 cycle
LD18123A-5
RXIN0+/-
R1
R0
G0
R5
R4
R3
R2
R1
R0
G0
RXIN1+/-
G2
G1
B1
B0
G5
G4
G3
G2
G1
B1
RXIN12/-
B3
B2
DE
VS
HS
B5
B4
B3
B2
DE
4-3. Backlight driving
CN2 ,CN3
Used connector : BHR-02(8.0)VS-1N (JST)
Corresponding connector : SM02(8.0)B-BHS-1-TB(LF)(SN) or -1N-TB(LF)(SN) (JST)
Pin no. symbol
function
Color of FL cable
1
VHIGH Power supply for lamp
(High voltage side)
(Pink/Blue)
2
VLOW Power supply for lamp
(Low voltage side)
(White/Gray)
5. Absolute Maximum Ratings
Parameter
+3.3V / +5.0V
Symbol
Vcc
Condition
Ta=25 oC
Pin name
Vcc
Ratings
0 to + 6.0
supply voltage
Input voltage
VI1
Ta=25oC RXINi-/+(i= 0,1,2) -0.3 to Vcc+0.3
RXCLK IN-/+
-0.3 to 3.3V
VI2
Ta=25oC
R/L , U/D
-0.3 to Vcc+0.3
Lamp input voltage VHIGH
-
-
1800
Storage temperature
Tstg
-
-
-30 to +80
Operating temperature Topa Panel surface
-
-30 to +80
[Note1] Humidity: 95%RH Max. at Ta=<40oC.
Maximum wet-bulb temperature at 39oC or less at Ta>40 oC.
No condensation.
Unit
V
V
V
V
Vrms
oC
oC
Remark
Vcc<3.0V
3.0V≦Vcc
[Note1]
6.Recommended operation condition
Parameter
Symbol
Supply voltage
Vcc
LVDS Signals
VL
Input voltage
VI
Ambient temperature Topa
Min.
+3.0
0
0
-30
Typ.
+3.3/+5.0
Max.
+5.5
2.4
Vcc
+80
Unit
Remark
V [Note1]
V [Note2]
V [Note3]
℃ [Note4], [Note5]