LCP-06008A-18
(15)Reliability Test Conditions for TFT-LCD Module
Table 12
No.
Test items
Test conditions
1 High temperature storage test Ta=+70℃
240h
2 Low temperature storage test
Ta=-20℃
240h
3 High temperature and
Tp=+40℃ , 95%RH
240h
high humidity operating test
(But no condensation of dew)
4 High temperature operating test Tp=+60℃
240h
5 Low temperature operating test Tp=-10℃
240h
6 Electro static discharge test
±200V・200pF(0Ω) to Terminals(Contact)
(1 time for each terminals)
7 Shock tset
980 m/s2, 6 ms
±X,±Y,±Z 3 times for each direction
(JIS C0041, A-7 Condition C)
8 Vibration test
Frequency range: 10Hz~55~10Hz
Stroke: 1.5 mm Sweep: 10Hz~55Hz
X,Y,Z 2 hours for each direction (total 6 hours)
(JIS C0040,A-10 Condition A)
9 Heat shock test
Ta=-20℃~+70℃ / 5 cycles
(1h) (1h)
10 Point activation test
Hit it 1,000,000 times with a silicon rubber of R8 HS 60.
(Touch panel)
Hitting force :2.45N(250gf)
Hitting speed : 3 times per second
11 Writing friction resistance test
(Touch panel)
Slide Pen 100,000 times under following
conditions:
Pen : 0.8Rmm Polyacetal stylus
Load : 2.45N(250gf)
Speed : 3 strokes per second
Stroke : 35mm
Testing apparatus : shown in Fig.3
Motor
Weight
2.45N(250gf)
Stroke 35mm
Fig.3
Touch Panel