DC AND AC PARAMETERS
This section summarizes the operating and mea-
surement conditions, and the DC and AC charac-
teristics of the device. The parameters in the DC
and AC Characteristic tables that follow are de-
rived from tests performed under the Measure-
Table 8. Operating Conditions (M24512 – W)
Symbol
Parameter
VCC
Supply Voltage
TA
Ambient Operating Temperature
ment Conditions summarized in the relevant
tables. Designers should check that the operating
conditions in their circuit match the measurement
conditions when relying on the quoted parame-
ters.
Min.
Max.
Unit
2.5
5.5
V
–40
85
°C
Table 9. Operating Conditions (M24512 – R)
Symbol
Parameter
VCC
Supply Voltage
TA
Ambient Operating Temperature
Min.
Max.
Unit
1.8
5.5
V
–40
85
°C
Table 10. AC Measurement Conditions
Symbol
Parameter
CL
Load Capacitance
Input Rise and Fall Times
Input Levels
Input and Output Timing Reference Levels
Min.
Max.
100
50
0.2VCC to 0.8VCC
0.3VCC to 0.7VCC
Unit
pF
ns
V
V
Figure 10. AC Measurement I/O Waveform
Input Levels
0.8VCC
0.2VCC
Input and Output
Timing Reference Levels
0.7VCC
0.3VCC
AI00825B