M29F200T, M29F200B
Table 8. Instructions (1)
Mne.
Instr.
Cyc.
Addr. (3,7)
1+
RD (2,4)
Read/Reset
Memory Array
Data
Addr. (3,7) Byte
3+
Word
1st Cyc. 2nd Cyc. 3rd Cyc. 4th Cyc. 5th Cyc. 6th Cyc. 7th Cyc.
X
Read Memory Array until a new write cycle is initiated.
F0h
AAAAh
5555h
5555h
2AAAh
AAAAh
Read Memory Array until a new write cycle
5555h is initiated.
Data
AAh
55h
F0h
AS (4) Auto Select
Addr. (3,7) Byte
3+
Word
Data
AAAAh
5555h
AAh
5555h
2AAAh
55h
AAAAh
5555h
90h
Read Electronic Signature or Block
Protection Status until a new write cycle is
initiated. See Note 5 and 6.
PG Program
Addr. (3,7) Byte
4
Word
Data
AAAAh
5555h
AAh
5555h
2AAAh
55h
AAAAh
5555h
A0h
Program
Address Read Data Polling or Toggle Bit
until Program completes.
Program
Data
BE Block Erase
Addr. (3,7) Byte
6
Word
AAAAh
5555h
5555h
2AAAh
AAAAh
5555h
AAAAh
5555h
5555h
2AAAh
Block Additional
Address Block (8)
Data
AAh
55h
80h
AAh
55h
30h
30h
CE Chip Erase
Addr. (3,7) Byte
6
Word
AAAAh
5555h
5555h
2AAAh
AAAAh
5555h
AAAAh
5555h
5555h
2AAAh
AAAAh
5555h
Note 9
Data
AAh
55h
80h
AAh
55h
10h
ES (10)
Erase
Suspend
Addr. (3,7)
1
Data
X
Read until Toggle stops, then read all the data needed from any
Block(s) not being erased then Resume Erase.
B0h
ER
Erase
Resume
Addr. (3,7)
1
Data
X
Read Data Polling or Toggle Bits until Erase completes or Erase is
suspended another time
30h
Notes: 1. Commands not interpreted in this table will default to read array mode.
2. A wait of tPLYH is necessary after a Read/Reset command if the memory was in an Erase or Program mode
before starting any new operation.
3. X = Don’t Care.
4. The first cycles of the RD or AS instructions are followed by read operations. Any number of read cycles can occur after
the command cycles.
5. Signature Address bits A0, A1 at VIL will output Manufacturer code (20h). Address bits A0 at VIH and A1 at VIL will output
Device code.
6. Block Protection Address: A0 at VIL, A1 at VIH and A12-A16 within the Block will output the Block Protection status.
7. For Coded cycles address inputs A15 and A16 are don’t care.
8. Optional, additional Blocks addresses must be entered within the erase timeout delay after last write entry,
timeout status can be verified through DQ3 value (see Erase Timer Bit DQ3 description).
When full command is entered, read Data Polling or Toggle bit until Erase is completed or suspended.
9. Read Data Polling, Toggle bits or RB until Erase completes.
10.During Erase Suspend, Read and Data Program functions are allowed in blocks not being erased.