6. Pulse output
The bits of the remote control word, as indicated by the addressed ROM locations, are loaded into a shift
register every bit-time this register is shifted. The output is used to generate a logic1 in the biphase (Manchester)
coding, modulated with a frequency of 36 KHz. The duty factor of the modulation pulses may be selected
(optionally) to be 25% or 33.3%. The output of the pulse generator controls the output driver that can provide a
maximum current of 5 mA.
DR5
DR4
DR3
DR2
DR1
DR0
DR6
SN0
SN7
SN1
SN2
SN3
SN6
SN4
SN5
Scan timing.
HANGZHOU SILAN MICROELECTRONICS JOINT-STOCK CO.,LTD
REV: 1.3
7