MB84VA2006-10/MB84VA2007-10
Table 7 Flash Memory Command Definitions
Command
Sequence
Bus
Write
Cycles
First Bus
Write Cycle
Second Bus Third Bus
Write Cycle Write Cycle
Fourth Bus
Read/Write
Cycle
Fifth Bus
Write Cycle
Sixth Bus
Write
Cycle
Reqโ€™d Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
Read/
Reset
word
Byte
1
XXXH F0H โ€”
โ€”โ€”โ€”
โ€” โ€” โ€” โ€”โ€”โ€”
Read/
Reset
word
Byte
3
555H
AAAH
AAH
2AAH
555H
55H
555H
AAAH
F0H
RA
RD
โ€”
โ€”โ€”โ€”
Autoselect
word
Byte
3
555H
AAAH
AAH
2AAH
555H
55H
555H
AAAH
90H
โ€”
โ€”
โ€”
โ€”โ€”โ€”
Program
word
Byte
4
555H
AAAH
AAH
2AAH
555H
55H
555H
AAAH
A0H
PA
PD
โ€”
โ€”โ€”โ€”
Chip
Erase
word
Byte
6
555H
AAAH
AAH
2AAH
555H
55H
555H
AAAH
80H
555H
AAAH
AAH
2AAH
555H
55H
555H
AAAH
10H
Sector
Erase
word
Byte
6
555H
AAAH
AAH
2AAH
555H
55H
555H
AAAH
80H
555H
AAAH
AAH
2AAH
555H
55H
SA
30H
Sector Erase Suspend Erase can be suspended during sector erase with Addr (โ€œHโ€ or โ€œLโ€). Data (B0H)
Sector Erase Resume Erase can be resumed after suspend with Addr (โ€œHโ€ or โ€œLโ€). Data (30H)
Set to word
Fast Mode Byte
3
555H
AAAH
AAH
2AAH
555H
55H
555H
AAAH
20H
โ€”
โ€”
โ€”
โ€”โ€”โ€”
Fast
word
XXXH
Program
2
A0H PA PD โ€” โ€” โ€” โ€” โ€” โ€” โ€” โ€”
(Note) Byte
XXXH
Reset word
XXXH
XXXH
from Fast
2
90H
F0H โ€” โ€” โ€” โ€” โ€” โ€” โ€” โ€”
Mode
Byte
XXXH
XXXH
Extended word
Sector
4
Protect Byte
XXXH 60H SPA 60H SPA 40H SPA SD โ€”
โ€”โ€”โ€”
Address bits A11 to A20 = X = โ€œHโ€ or โ€œLโ€ for all address commands except for Program Address (PA) and Sector
Address (SA).
Bus operations are defined in Table 2.
Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
RA =Address of the memory location to be read.
PA =Address of the memory location to be programmed. Addresses are latched on the falling edge of
the write pulse.
SA =Address of the sector to be erased. The combination of A20, A19, A18, A17, A16, A15, A14, and A13 will
uniquely select any sector.
RD =Data read from location RA during read operation.
PD =Data to be programmed at location PA.
SPA =Sector address to be protected. Set sector address (SA) and (A6, A1, A0) = (0, 1, 0).
SD =Sector protection verify data. Output 01H at protected sector addresses and output 00H at unprotected
sector addresses.
Note:This command is valid while Fast Mode.