MB89130/130A Series
Figure 2 Operating Voltage vs. Main Clock Operating Frequency
(Dual-clock MB89131/133/133A/135/135A)
6
5
4
Operation assurance range
3
2
1
1
2
3
4
Main clock oprating frequency (at an instruction cycle of 4/FCH) (MHz)
4.0
2.0
1.0
Minimum execution time (Instruction cycle) (µs)
Figure 1 and 2 indicate the operating frequency of the external oscillator at an instruction cycle of 4/FCH.
Since the operating voltage range is dependent on the instruction cycle, see minimum execution time if the oper-
ating speed is switched using a gear.
WARNING: The recommended operating conditions are required in order to ensure the normal operation of the
semiconductor device. All of the device’s electrical characteristics are warranted when the device is
operated within these ranges.
Always use semiconductor devices within their recommended operating condition ranges. Operation
outside these ranges may adversely affect reliability and could result in device failure.
No warranty is made with respect to uses, operating conditions, or combinations not represented on
the data sheet. Users considering application outside the listed conditions are advised to contact their
FUJITSU representatives beforehand.