DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MBM29F017A View Datasheet(PDF) - Spansion Inc.

Part Name
Description
Manufacturer
MBM29F017A
Spansion
Spansion Inc. Spansion
MBM29F017A Datasheet PDF : 49 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MBM29F017A-70/-90/-12
MBM29F017A Command Definitions Table
Command
Sequence
Read/Reset*1
Reset/Read*1
Autoselect
Byte Program
Chip Erase
Sector Erase
Sector Erase
Suspend
Sector Erase
Resume
Bus First Bus Second Bus Third Bus
Write Write Cycle Write Cycle Write Cycle
Cycles
Fourth Bus
Read/Write
Cycle
Fifth Bus
Write Cycle
Sixth Bus
Write Cycle
Req'd Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data Addr. Data
1 XXXh F0h — — — — — — — — — —
3 XXXh AAh XXXh 55h XXXh F0h RA*2 RD*2 — — — —
3 XXXh AAh XXXh 55h XXXh 90h IA*2 ID*2 — — — —
4 XXXh AAh XXXh 55h XXXh A0h PA PD — — — —
6 XXXh AAh XXXh 55h XXXh 80h XXXh AAh XXXh 55h XXXh 10h
6 XXXh AAh XXXh 55h XXXh 80h XXXh AAh XXXh 55h SA 30h
1 Erase can be suspended during sector erase with Addr (“H” or “L”). Data (B0h)
1 Erase can be resumed after suspend with Addr (“H” or “L”). Data (30h)
*1 : Either of the two reset commands will reset the device.
*2 : The fourth bus cycle is only for read.
Notes : Bus operations are defined in “MBM29F017A User Bus Operations”.
RA = Address of the memory location to be read.
IA= Autoselect read address that sets A6, A1, A0.
PA= Address of the memory location to be programmed. Addresses are latched on the falling edge
of the WE pulse.
SA = Address of the sector to be erased. The combination of A20, A19, A18, A17, and A16 will uniquely select
any sector.
RD = Data read from location RA during read operation.
ID= Device code/manufacture code for the address located by IA.
PD = Data to be programmed at location PA. Data is latched on the rising edge of WE.
Read and Byte program functions to non-erasing sectors are allowed in the Erase Suspend mode.
The command combinations not described in “MBM29F017A Command Definitions” are illegal.
MBM29F017A Sector Protection Verify Autoselect Codes Table
Type
Manufacture’s
Code
A18 to A20
XXX
A6
A1
A0
Code
(HEX)
DQ7
DQ6
DQ5
DQ4
DQ3
DQ2
DQ1
DQ0
VIL VIL VIL 04h 0 0 0 0 0 1 0 0
Device Code
X X X VIL VIL VIH 3Dh 0 0 1 1 1 1 0 1
Sector Group
Protection
Sector Group
Addresses
VIL VIH VIL 01h*
0
0
0
0
0
0
0
1
* : Outputs 01h at protected sector addresses and outputs 00h at unprotected sector addresses.