MC10EP016, MC100EP016
Table 12. AC CHARACTERISTICS VEE = -3.0 V to -5.5 V; VCC = 0 V or VCC = 3.0 V to 5.5 V; VEE = 0 V (Note 25)
-40 °C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
fCOUNT Maximum Frequency
Q, TC
COUT/COUT
>1
> 800
>1
> 800
>1
> 800
GHz
MHz
tPLH
Propagation Delay (10)
CLK to Q 300 460 600 350 500 650 400 560 700 ps
tPHL
(10)
MR to Q 300 400 500 400 500 600 450 580 700
(10) CLK to TC 350 420 550 400 500 600 400 550 700
(10)
MR to TC 250 350 450 350 450 550 400 510 600
(10) CLK to COUT 400 470 650 450 550 700 450 600 800
(10) MR to COUT 300 400 550 400 500 650 450 560 700
(100) CLK to Q 350 500 650 400 550 700 480 630 780
(100)
MR to Q 400 550 700 450 590 750 520 670 820
(100) CLK to TC 350 500 650 400 550 700 480 630 780
(100) MR to TC 400 550 700 450 590 750 520 670 820
(100) CLK to COUT 400 550 750 450 600 800 530 680 880
(100) MR to COUT 450 600 800 500 640 850 570 720 920
tS
Setup Time
Pn 100 -50
100 -50
100 -50
ps
CE 500 300
500 300
500 300
PE 500 300
500 300
500 300
TCLD 500 300
500 300
500 300
tH
Hold Time
Pn 100 -50
100 -50
100 -50
ps
CE 500 300
500 300
500 300
PE 500 300
500 300
500 300
TCLD 500 300
500 300
500 300
tJITTER Clock Random Jitter
(RMS >1000 Waveforms)
2.6 8.5
2.5 8.0
2.5 8.0 ps
tRR
Reset Recovery Time
tPW
Minimum Pulse Width CLK, MR
tr
Output Rise/Fall Times
tf
20% - 80%
200 80
200 80
200 80
ps
550 300
550 300
550 300
ps
120 210 320 120 220 320 150 250 450 ps
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
25. Measured using a 750 mV source, 50% duty cycle clock source. All loading with 50 W to VCC - 2.0 V.
http://onsemi.com