DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MC33996 View Datasheet(PDF) - Freescale Semiconductor

Part Name
Description
Manufacturer
MC33996
Freescale
Freescale Semiconductor Freescale
MC33996 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
STATIC ELECTRICAL CHARACTERISTICS
Table 3. STATIC ELECTRICAL CHARACTERISTICS
Characteristics noted under conditions 3.1V SOPWR 5.5V, 5.0V VPWR 18V, -40°C TA 125°C unless otherwise noted.
Where applicable, typical values noted reflect the parameter ‘s approximate value with VPWR = 13V, TA = 25°C.
Characteristic
Symbol
Min
Typ
Max
Unit
POWER SUPPLY (VPWR)
Supply Voltage Range
Fully Operational
Supply Current
All Outputs ON, IOUT = 0.3A
Sleep State Supply Current at RST 0.8 and/or
SOPWR 1.5V
Over-voltage Shutdown
Over-voltage Shutdown Hysteresis
VPWR Under-voltage Shutdown
SPI Interface Logic Supply Voltage
SPI Interface Logic Supply Current (RST Pin High)
SPI Interface Logic Supply Current (RST Pin Low)
SPI Interface Logic Supply Under-voltage Lockout
Threshold
VPWR (FO)
IPWR (ON)
IPWR (SS)
VOV
VOV (HYS)
VPWR (UV)
SOPWR
ISOPWR(RSTH)
ISOPWR(RSTL)
SOPWR (UNVOL)
5.0
_
27.5
0.6
3.1
100
-10
1.5
4.0
1.0
31.5
1.4
3.2
2.5
V
27
mA
8.0
10
μA
35
V
2.3
V
4.0
V
5.5
V
500
μA
10
μA
3.0
V
POWER OUTPUT (VPWR)
Drain-to-Source ON Resistance (IOUT = 0.35A, VPWR =
RDS(ON)
13V)
TJ = 125°C
TJ = 25°C
TJ = -40°C
Ω
0.75
1.1
0.55
0.45
Output Self-Limiting Current
Outputs Programmed ON
I OUT (lim)
A
0.9
1.2
2.5
Output Fault Detect Threshold (10)
Outputs Programmed OFF
VOUTth (F)
V
2.5
3.0
3.5
Output Off Open Load Detect Current (11)
I OCO
Outputs Programmed OFF (VPWR = 5.0V, 13V, 18V)
25
μA
50
100
Output Clamp Voltage
IOUT = 20mA
VCL
V
45
50
55
Output Leakage Current
SOPWR 1.5V, VOUT 1-16 = 18V
IOUT(lkg)
μA
-10
2.0
10
Over-temperature Shutdown (Outputs OFF) (12)
Over-temperature Shutdown Hysteresis (12)
TLIM
155
165
180
°C
TLIM (hys)
5.0
10
20
°C
Notes
10. Output Fault Detect Thresholds with outputs programmed OFF. Output Fault Detect Thresholds are the same for output open and
shorts.
11. Output OFF Open Load Detect Current is the current required to flow through the load for the purpose of detecting the existence of an
open load condition when the specific output is commanded to be OFF.
12. This parameter is guaranteed by design; however, it is not production tested.
Analog Integrated Circuit Device Data
Freescale Semiconductor
33996
5

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]