NanoAmp Solutions, Inc.
NT5DS64M4CT, NT5DS32M8CT, NT5DS16M16CT
NT5DS64M4CS, NT5DS32M8CS, NT5DS16M16CS
Operating Mode
The normal operating mode is selected by issuing a Mode Register Set Command with bits A7-A12 to zero, and bits A0-A6 set
to the desired values. A DLL reset is initiated by issuing a Mode Register Set command with bits A7 and A9-A12 each set to
zero, bit A8 set to one, and bits A0-A6 set to the desired values. A Mode Register Set command issued to reset the DLL should
always be followed by a Mode Register Set command to select normal operating mode.
All other combinations of values for A7-A12 are reserved for future use and/or test modes. Test modes and reserved states
should not be used as unknown operation or incompatibility with future versions may result.
CAS Latencies
CK
CK
Command
DQS
DQ
Read
NOP
CL=2
NOP
CAS Latency = 2, BL = 4
NOP
NOP
NOP
CK
CK
Command
DQS
DQ
Read
NOP
CL=2.5
NOP
Shown with nominal tAC, tDQSCK, and tDQSQ.
CAS Latency = 2.5, BL = 4
NOP
NOP
NOP
Don’t Care
DOC # 14-02-044 Rev A ECN # 01-1116