CHARACTERISTICS AND SPECIFICATIONS:
POWER INPUT:
• Voltage: 8-30 VDC
• Current Draw: 125mA @ 24VDC, with all options equipped.
• Reverse polarity protected
PICKUP INPUT:
RF Pickup:
• Modulation Carrier Frequency: 20KHz
• Input Frequency: 2 Hz to 5KHz, adjustable trigger level
• Trigger Sensitivity: 20 millivolt peak to peak (minimum)
• Carrier Adjustment: to allow precise tuning of carrier signal to physical environment (e.g. air gap,
wall thickness)
• Maximum Air Gap: 0.160”
• Preferred Coil Inductance: 1.0 milliHenry +/- 10%
• Maximum Distance From Pickup To Preamplifier 100 feet
Magnetic Pickup:
• Input protected, RF and band pass filtered
• Input Frequency: 0 to 10KHz, adjustable trigger level
• Trigger Sensitivity: 4 millivolt RMS (minimum)
NOTE: At 4mV frequency range 10 Hz to 3KHz
• Input Impedance: 40K Ohms (nominal)
• Maximum Input Signal: 600 Volts RMS
• Maximum Distance From Pickup To Preamp: 100 feet
PULSE OUTPUTS:
• TTL/CMOS (Standard); Fan-out of 5 TTL/CMOS loads
• Open Collector: Maximum OFF state voltage 30 VDC
Maximum ON current 0.40 amps
• 0 to 10 VDC square wave
• Square wave tied to input voltage
• Pulse scaling (option): ÷2, ÷4, ÷8, ÷16, ÷32, ÷64, or ÷128 user selectable.
CURRENT OUTPUT OPTION:
• Accuracy +/- 0.05% of full-scale +/-200 PPM/°C.
• Available range 4 to 20mA.
• Output suitable for driving floating or grounded loads.
• Maximum loop impedance 500 ohms.
• Response time 0.3 seconds for 10 to 90 %.
VOLTAGE OUTPUT OPTION:
• Accuracy +/- 0.05% of full-scale +/-200 PPM/°C.
• Available range 0 to 5VDC or 0 to 10VDC, user selectable.
• Impedance less than 10 ohms.
• Response time 0.3 seconds for 10 to 90 %.
PA1001A – 7/02