Philips Semiconductors Programmable Logic Devices
Programmable logic sequencer
(16 × 45 × 12)
Product specification
PLS159A
LOGIC PROGRAMMING
The PLS159A is fully supported by industry
standard (JEDEC compatible) PLD CAD
tools, including Philips Semiconductors’
SNAP, Data I/O Corporation’s ABELand
Logical Devices Inc.’s CUPLdesign
software packages.
All packages allow Boolean and state
equation entry formats. SNAP, ABEL and
CUPL also accept, as input, schematic
capture format.
“AND” ARRAY – (I), (B), (Qp)
I, B, Q
I, B, Q
I, B, Q
I, B, Q
PLS159A logic designs can also be
generated using the program table entry
format detailed on the following pages. This
program table entry format is supported by
the Philips Semiconductors SNAP PLD
design software package.
To implement the desired logic functions, the
state of each logic variable from logic
equations (I, B, O, P, etc.) is assigned a
symbol. The symbols for TRUE,
COMPLEMENT, INACTIVE, PRESET, etc.,
are defined below.
PROGRAMMING AND
SOFTWARE SUPPORT
Refer to Section 9 (Development Software)
and Section 10 (Third-party Programmer/
Software Support) of this data handbook for
additional information.
I, B, Q
I, B, Q
I, B, Q
I, B, Q
I, B, Q
I, B, Q
I, B, Q
I, B, Q
(T, FC, L, P, R, D)n
STATE
INACTIVE1, 2
CODE
O
STATE
I, B, Q
(T, FC, L, P, R, D)n
CODE
H
“COMPLEMENT” ARRAY – (C)
C
C
STATE
I, B, Q
(T, FC, L, P, R, D)n
CODE
L
(T, FC, L, P, R, D)n
STATE
CODE
DON’T CARE
C
C
C
(Tn, FC)
ACTION
INACTIVE1, 3, 5
CODE
O
C
(Tn, FC)
ACTION
GENERATE5
CODE
A
C
(Tn, FC)
ACTION
PROPAGATE
CODE
C
(Tn, FC)
ACTION
TRANSPARENT
CODE
“OR” ARRAY – (F-F CONTROL MODE)
“OR” ARRAY – (Qn = D-Type)
FC
FC
Tn
Tn
J
Q
J
Q
J
Q
J
Q
ENABLED
M
DISABLED
M
M = ENABLED
M = ENABLED
K
K
K
K
ACTION
J–K OR D
(CONTROLLED)1
CODE
A
Notes on following page.
ACTION
J–K ONLY
CODE
Tn STATUS
ACTIVE (Set)1
CODE
A
Tn STATUS
INACTIVE (Reset)
CODE
CAUTION:
THE PLS159A Programming Algorithm is different from the PLS159.