IS63LV1024
OPERATING RANGE
Range
Commercial
Industrial
Ambient Temperature
0°C to +70°C
40°C to +85°C
VCC
3.3V ± 0.3V
3.3V ± 0.3V
DC ELECTRICAL CHARACTERISTICS (Over Operating Range)
Symbol
VOH
VOL
VIH
VIL
ILI
Parameter
Output HIGH Voltage
Output LOW Voltage
Input HIGH Voltage
Input LOW Voltage(1)
Input Leakage
Test Conditions
VCC = Min., IOH = 4.0 mA
VCC = Min., IOL = 8.0 mA
GND ≤ VIN ≤ VCC
ILO
Output Leakage
GND ≤ VOUT ≤ VCC, Outputs Disabled
Notes:
1. VIL = 3.0V for pulse width less than 10 ns.
2. The Vcc operating range for 8 ns is 3.3V +10%, -5%.
Com.
Ind.
Com.
Ind.
Min.
Max.
Unit
2.4
V
0.4
V
2.2 VCC + 0.3 V
0.3
0.8
V
2
2
µA
5
5
2
2
µA
5
5
POWER SUPPLY CHARACTERISTICS(1) (Over Operating Range)
Symbol Parameter
Test Conditions
-8 ns
-10 ns
-12 ns
-15 ns
Min. Max. Min. Max. Min. Max. Min. Max. Unit
ICC Vcc Operating VCC = Max., CE = VIL Com.
160
150
140
130 mA
Supply Current IOUT = 0 mA, f = Max.
Ind.
170 160 150
140
ISB TTL Standby
Current
(TTL Inputs)
VCC = Max.,
VIN = VIH or VIL
CE ≥ VIH, f = 0
Com.
30
30
30
30 mA
Ind.
40
40
40
40
ISB
CMOS Standby VCC = Max.,
Com.
10
10
10
10 mA
Current
CE ≤ VCC 0.2V,
Ind.
15
15
15
15
(CMOS Inputs) VIN > VCC 0.2V, or
VIN ≤ 0.2V, f = 0
Notes:
1. At f = fMAX, address and data inputs are cycling at the maximum frequency, f = 0 means no input lines change.
CAPACITANCE(1,2)
Symbol
CIN
CI/O
Parameter
Input Capacitance
Input/Output Capacitance
Conditions
VIN = 0V
VOUT = 0V
Max.
Unit
6
pF
8
pF
Notes:
1. Tested initially and after any design or process changes that may affect these parameters.
2. Test conditions: TA = 25°C, f = 1 MHz, Vcc = 3.3V.
Integrated Circuit Solution Inc.
3