IS63LV1024
READ CYCLE SWITCHING CHARACTERISTICS(1) (Over Operating Range)
-8 ns
-10 ns
-12 ns
-15 ns
Symbol Parameter
Min. Max.
Min. Max.
Min. Max.
Min. Max.
Unit
tRC Read Cycle Time
8
10
12
15
ns
tAA Address Access Time
8
10
12
15
ns
tOHA Output Hold Time
3
3
3
3
ns
tACE CE Access Time
8
10
12
15
ns
tDOE OE Access Time
4
5
6
7
ns
tLZOE(2) OE to Low-Z Output
0
0
0
0
ns
tHZOE(2) OE to High-Z Output
0
4
0
5
0
6
0
7
ns
tLZCE(2) CE to Low-Z Output
3
3
3
3
ns
tHZCE(2) CE to High-Z Output
0
4
0
5
0
6
0
7
ns
Notes:
1. Test conditions assume signal transition times of 3 ns or less, timing reference levels of 1.5V, input pulse levels of 0 to 3.0V
and output loading specified in Figure 1a.
2. Tested with the load in Figure 1b. Transition is measured ±500 mV from steady-state voltage. Not 100% tested.
AC TEST CONDITIONS
Parameter
Input Pulse Level
Input Rise and Fall Times
Input and Output Timing
and Reference Levels
Output Load
Unit
0V to 3.0V
3 ns
1.5V
See Figures 1a and 1b
Notes:
1. The Vcc operating range for 8 ns is 3.3V +10%, -5%.
AC TEST LOADS
ZOUT = 50 Ω
OUTPUT
50 Ω
VT = 1.5V
Figure 1a.
3.3V
317 Ω
OUTPUT
5 pF
Including
jig and
scope
351 Ω
Figure 1b.
4
Integrated Circuit Solution Inc.
SR019-0C