Si3000
Table 8. Digital FIR Filter Characteristics—Transmit and Receive
(VA, VD = 5 V ±5% or 3.3 V ±10%, Sample Rate = 8 kHz, TA = 0 to 70°C)
Parameter
Symbol
Min
Typ
Passband (3 dB, HPFD = 1)
Passband (3 dB, HPFD = 0)
F(3 dB)
0
—
F(3 dB)
0.01
—
Passband Ripple Peak-to-Peak
–0.1
—
Stopband
—
4.4
Stopband Attenuation
–74
—
Group Delay
tgd
—
12/Fs
Note: Typical FIR filter characteristics for Fs = 8000 Hz are shown in Figures 3, 4, 5, and 6.
Max
3.6
3.6
0.1
—
—
—
Unit
kHz
kHz
dB
kHz
dB
sec
Table 9. Digital IIR Filter Characteristics—Transmit and Receive
(VA, VD = 5 V ±5% or 3.3 V ±10%, Sample Rate = 8 kHz, TA = 70°C)
Parameter
Symbol
Min
Typ
Max
Unit
Passband (3 dB, HPFD = 1)
Passband (3 dB, HPFD = 0)
F(3 dB)
0
—
F(3 dB)
0.01
—
3.6
kHz
3.6
kHz
Passband Ripple Peak-to-Peak
–0.2
—
0.2
dB
Stopband
—
4.4
—
kHz
Stopband Attenuation
–40
—
—
dB
Group Delay
tgd
—
1.6/Fs
—
sec
Note: Typical IIR filter characteristics for Fs = 8000 Hz are shown in Figures 7, 8, 9, and 10. Figures 11 and 12 show group
delay versus input frequency.
Rev. 1.4
9