Other Specifications
Characteristic
Switching frequency
Weight
Coplanarity
SMT05E Series | 5SXAA1D0CS-erDieCs C|on1v5eWrtDeCrs/DC
E Class Non-Isolated
Symbol
Min
Typ
Max
Units
Notes and Conditions
Fsw
330
kHz
Fixed frequency
3
g
100
µm
Measured from seating plane
Environmental Specifications
Characteristic
Symbol
Min
Typ
Max
Units
Notes and Conditions
Thermal performance
-40
100
ºC
See Note 5 and individual
derating curves
EMC
Electromagnetic Compatibility
Phenomenon
Port
Immunity:
Conducted immunity
Radiated immunity
ESD
Enclosure
Standard Test level Criteria Notes and conditions
EN61000-4-6
EN61000-4-3
EN61000-4-2 6kV contact NP
8kV air
As per ETS 300 386-1 table 5
Performance criteria:
NP: Normal Performance: EUT shall withstand applied test and operate within relevant limits as specified without damage.
RP: Reduced Performance: EUT shall withstand applied test. Reduced performance is permitted within specified limits, resumption to
normal performance shall occur at the cessation of the test.
LFS: Loss of Function (self recovery): EUT shall withstand applied test without damage, temporary loss of function permitted during test.
Unit will self recover to normal performance after test.
Referenced ETSI standards:
ETS 300 386-1 table 5 (1997): Public telecommunication network equipment, EMC requirements
ETS 300 132-2 (1996): Power supply interface at the input to telecommunication equipment: Part 2 operated by direct current (DC)
ETR 283 (1997): Transient voltages at interface A on telecommunication direct current (DC) power distributions
4