DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TDA6404 View Datasheet(PDF) - Philips Electronics

Part Name
Description
Manufacturer
TDA6404 Datasheet PDF : 32 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Philips Semiconductors
5 V mixer/oscillator-PLL synthesizers for
hyperband tuners
Product specification
TDA6404; TDA6405;
TDA6405A
handbook, halfpage
UHFIN1 1
28 VHFOSCIB2
UHFIN2 2
27 VHFOSCOC2
VHFIN 3
26 VHFOSCOC1
RFGND 4
25 VHFOSCIB1
IFFIL1 5
24 UHFOSCIB2
IFFIL2 6
23 UHFOSCOC2
PVHFL 7
PVHFH 8
22 UHFOSCOC1
TDA6404
21 UHFOSCIB1
PUHF 9
20 GND
AS 10
19 IFOUT2
SDA 11
18 IFOUT1
SCL 12
ADC 13
17 VCC
16 XTAL
CP 14
15 VT
MGK830
Fig.2 Pin configuration for TDA6404.
handbook, halfpage
VHFOSCIB2 1
28 UHFIN1
VHFOSCOC2 2
27 UHFIN2
VHFOSCOC1 3
26 VHFIN
VHFOSCIB1 4
25 RFGND
UHFOSCIB2 5
24 IFFIL1
UHFOSCOC2 6
23 IFFIL2
UHFOSCOC1 7 TDA6405 22 PVHFL
UHFOSCIB1 8 TDA6405A 21 PVHFH
GND 9
20 PUHF
IFOUT2 10
19 AS
IFOUT1 11
18 SDA
VCC 12
XTAL 13
17 SCL
16 ADC
VT 14
15 CP
MGK831
Fig.3 Pin configuration for TDA6405(A)
FUNCTIONAL DESCRIPTION
The devices are controlled via the I2C-bus.
For programming, there is one module address (7 bits)
and the R/W bit for selecting the read or write mode.
Write mode
Data bytes can be sent to the devices after the address
transmission (first byte) by setting the R/W bit to logic 0.
Four data bytes are needed to fully program the devices.
The I2C-bus transceiver has an auto-increment facility
which permits the programming of the devices within one
single transmission (address + 4 data bytes).
The devices can also be partially programmed, providing
that the first data byte following the address is divider
byte 1 (DB1) or control byte (CB). The bits in the data
bytes are defined in Tables 1 and 2.
The first bit of the data byte transmitted indicates whether
frequency data (first bit = 0) or control and band switch
data (first bit = 1) will follow. Until an I2C-bus STOP
condition is sent by the controller, additional data bytes
can be entered without the need to re-address the devices.
The frequency register is loaded after the 8th clock pulse
of the second divider byte (DB2). The control register is
loaded after the 8th clock pulse of the CB. The band switch
register is loaded after the 8th clock pulse of the band
switch byte (BB).
1999 Jan 13
6

Share Link: 