13 AC CHARACTERISTICS
SYMBOL
PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
Single-ended application; note 1
Po
output power
THD
total harmonic distortion
Gv(cl)
η
closed-loop voltage gain
efï¬ciency
Mono BTL application; note 5
Po
output power
THD
Gv(cl)
η
total harmonic distortion
closed loop voltage gain
efï¬ciency
RL = 4 Ω; THD = 0.5%; VP = ±25 V 50(2) 55
−
W
RL = 4 Ω; THD = 10%; VP = ±25 V 60(2) 65
−
W
RL = 4 Ω; THD = 0.5%; VP = ±27 V 60(2) 65
−
W
RL = 4 Ω; THD = 10%; VP = ±27 V 74(2) 80
−
W
Po = 1 W; note 3
fi = 1 kHz
−
0.01 0.05 %
fi = 10 kHz
−
0.1 −
%
29
30
31
dB
Po = 30 W; fi = 1 kHz; note 4
−
94
−
%
RL = 8 Ω; THD = 0.5%; VP = ±25 V 100(2) 112 −
W
RL = 8 Ω; THD = 10%; VP = ±25 V 128(2) 140 −
W
RL = 4 Ω; THD = 0.5%; VP = ±17 V 80(2) 87
−
W
RL = 4 Ω; THD = 10%; VP = ±17 V 100(2) 110 −
W
Po = 1 W; note 3
fi = 1 kHz
fi = 10 kHz
−
0.01 0.05 %
−
0.1 −
%
35
36
37
dB
Po = 30 W; fi = 1 kHz; note 4
−
94
−
%
Notes
1. VP = ±25 V; RL = 4 Ω; fi = 1 kHz; Tamb = 25 °C; measured in reference design in Figs 9 and 11; unless otherwise
specified.
2. Indirectly measured; based on Rds(on) measurement.
3. Total Harmonic Distortion (THD) is measured in a bandwidth of 22 Hz to 22 kHz. When distortion is measured using
a low-order low-pass filter a significantly higher value will be found, due to the switching frequency outside the audio
band.
4. Efficiency for power stage; output power measured across the loudspeaker load.
5. VP = ±25 V; RL = 8 Ω; fi = 1 kHz; Tamb = 25 °C; measured in reference design in Figs 9 and 11; unless otherwise
specified.
2001 Dec 11