MC10H130
APPLICATION INFORMATION
The MC10H130 is a clocked dual D type latch. Each
latch may be clocked separately by holding the common
clock in the low state, and using the clock enable inputs
for the clocking function. If the common clock is to be used
to clock the latch, the clock enable (CE) inputs must be
in the low state. In this mode, the enable inputs perform
the function of controlling the common clock (C).
Any change at the D input will be reflected at the output
while the clock is low. The outputs are latched on the
positive transition of the clock. While the clock is in the
high state, a change in the information present at the data
inputs will not affect the output information.
The set and reset inputs do not override the clock and
D inputs. They are effective only when either C or CE or
both are high.
MOTOROLA
2–50
MECL Data
DL122 — Rev 6