BAS 19
… BAS 21
Electrical Characteristics
at TA = 25 ˚C, unless otherwise specified.
Parameter
DC characteristics
Breakdown voltage1)
I(BR) = 100 µA
Forward voltage
IF = 100 mA
IF = 200 mA
Reverse current
VR = VR max
VR = VR max; Tj = 150 ˚C
BAS 19
BAS 20
BAS 21
AC characteristics
Diode capacitance
VR = 0 V, f = 1 MHz
Reverse recovery time
IF = 30 mA, IR = 30 mA, RL = 100 Ω
measured at IR = 3 mA
Test circuit for reverse recovery time
Symbol
Values
Unit
min. typ. max.
V(BR)
VF
IR
120 –
200 –
250 –
–
–
–
–
–
–
–
–
V
–
–
–
1
1.25
100 nA
100 µA
CD
–
–
5
pF
trr
–
–
50 ns
Pulse generator: tp = 100 ns, D = 0.05
tr = 0.6 ns, Rj = 50 Ω
Oscillograph: R = 50 Ω
tr = 0.35 ns
C ≤ 1 pF
1) Pulse test: tp ≤ 300 µs, D = 2 %.
Semiconductor Group
2