VR37
Vishay BCcomponents
High Ohmic/High Voltage Resistors
TEST PROCEDURES AND REQUIREMENTS
IEC
60 115-1
CLAUSE
IEC
60 068-2
TEST
METHOD
TEST
PROCEDURE
4.7
voltage proof on insulation
700 V (RMS) during 1 minute; V-block
method
4.12
noise
“IEC publication 60195”
REQUIREMENTS
no breakdown
max. 2.5 µV/V
4.6.1.1
4.13
insulation resistance
short time overload
500 V (DC) during 1 minute; V-block
method
Rins min.: 104 MΩ
room temperature;
dissipation 6.25 × Pn (voltage not more
than 2 × limiting voltage);
10 cycles; 5 s on and 45 s off
∆R/R max.: ± 2.0 % + 0.05 Ω
www.vishay.com
6
For technical questions contact: ff3dresistors@vishay.com
Document Number: 28733