DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

HL1-H-AC100V-F View Datasheet(PDF) - Panasonic Corporation

Part Name
Description
Manufacturer
HL1-H-AC100V-F
Panasonic
Panasonic Corporation Panasonic
HL1-H-AC100V-F Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
HL
RATING
1. Coil data
1) AC coils
Nominal coil
voltage
6V AC
12V AC
24V AC
48V AC
100/110V AC
110/120V AC
200/220V AC
Nominal coil current
(mA)
50Hz
60Hz
224
200
111
100
56
50
28
25
13.4/14.7 12/13.2
12.2/13.5 10.9/11.9
6.7/7.4
6/6.6
Nominal operating power
(VA)
50Hz
60Hz
1.3
1.2
1.3
1.2
1.3
1.2
1.3
1.2
1.3
1.2
1.3
1.2
1.3
1.2
Pick-up voltage
(at 20°C 68°F)
80%V or less of
nominal voltage
(Initial)
Drop-out voltage
(at 20°C 68°F)
30%V or more of
nominal voltage
(Initial)
Inductance (H)
When drop-out
0.078
0.312
1.243
4.974
23.75
27.19
85.98
When operating
0.074
0.295
1.181
4.145
20.63
25.57
81.76
Max. allowable
voltage
110%V of
nominal voltage
Notes: 1. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
In particular, for AC operation, if the applied voltage drops to 80% V or more below the rated voltage, humming will occur and a large current will flow leading possibly
to coil burnout.
2. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.
2) DC coils (at 20°C 68°F)
Nominal coil
voltage
Nominal coil current
(mA)
Nominal operating
power (W)
Coil resistance
()
Pick-up voltage
(at 20°C 68°F)
Drop-out voltage
(at 20°C 68°F)
Max. allowable voltage
(at 70°C 158°F)
6V DC
150
0.9
40
12V DC
75
24V DC
37
48V DC
18.5
0.9
0.9
0.9
160
650
2,600
80%V or less of
nominal voltage
(Initial)
10%V or more of
nominal voltage
(Initial)
110%V of
nominal voltage
100/110V DC
10
1.0
10,000
Notes: 1. The rated excitation current is ±10% (20°C 68°F).
2. The coil resistance for DC operation is the value measured when the coil temperature is 20°C 68°F. Compensate ±0.4% for every ±1°C change in temperature.
3. The relay operates in a range of 80% to 110% V of the voltage rating, but ideally, in consideration of temporary voltage fluctuations, it should be operated at the
rated voltage.
4. For use with 200 V DC, connect a 10 K(5W) resistor, in series, to the 100 V DC relay.
5. The maximum allowable voltage is the maximum voltage fluctuation value for the coil power supply. This value is not a permissible value for continuous operation.
(This value differs depending on the ambient temperature. Please contact us for details.)
2. Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Unit weight
Item
Initial contact resistance, max
Contact material
Nominal switching capacity
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Between open contacts
Between contact sets
Between contact and coil
Temperature rise
Operate time (at 20°C 68°F)*2
Release time (at 20°C 68°F)*2
Shock resistance
Vibration resistance
Mechanical
Functional
Destructive
Functional
Destructive
Electrical
AC load
DC load
Conditions for operation, transport and storage*3
Max. Operating speed
Specifications
Max. 50 m(By voltage drop 6 V DC 1A)
AgSnO2 type
1 Form C: 15A 125V AC, 10A 250V AC (resistive load)
2 Form C: 10A 125V AC (resistive load)
100mA 5V DC
Min. 100M(at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
1,500 Vrms for 1min. (Detection current: 10mA.)
2,000 Vrms for 1min. (Detection current: 10mA.)
Max. 80°C (By resistive method, nominal voltage)
DC type/AC type: Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
DC type/AC type: Max. 25ms (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 196 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10µs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.)
10 to 55 Hz at double amplitude of 2 mm
AC type: 5×107 (at 180 cpm), DC type: 108 (at 180 cpm)
1 Form C: 15A 125V AC, 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
2 Form C: 10A 250V AC resistive load (cosϕ=1) Life switching cycle: Min. 3×105
1 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
2 Form C: 3A 30V DC resistive load (cosϕ=1) Life switching cycle: Min. 5×105
Ambient temperature: –50°C to +70°C –58°F to +158°F (Without LED indication);
–50°C to +60°C –58°F to +140°F (With LED indication)
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm (at max. rating)
Approx. 35g 1.23 oz
Notes: If integrating into electrical appliances that will be subject to compliance to the Electrical Appliance and Material Safety Law, please use in an ambient temperature
between –50°C to +40°C –58°F to +104°F (AC type).
*1 This value can change due to the switching frequency, environmental conditions and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 For the AC coil types, the operate/release time will differ depending on the phase.
*3 The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value.Refer to 4. Conditions for operation,
transport and storage mentioned in AMBIENT ENVIRONMENT.
All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd.