DC Electrical Characteristics (Continued)
Symbol
Parameter
VCC
(V)
VCC—Cable
(V)
TA = 0°C
TA = −40°C
to +70°C
to +85°C
Guaranteed Limits
Units
Conditions
VOL
Maximum LOW
Level Output
An, HLH
Voltage
Bn, Yn
Bn, Yn
PLH
PLH
RD
Maximum Output
B1 - B8, Y9 -Y13
Impedance
Minimum Output
Impedance
B1 - B8, Y9 - Y13
3.0
3.0
0.2
3.0
3.0
0.4
3.0
3.0
0.8
3.0
4.5
0.77
3.0
3.0
0.85
3.0
4.5
0.8
3.3
3.3
60
3.3
5.0
55
3.3
3.3
30
3.3
5.0
35
0.2
IOL = 50 µA
0.4
IOL = 4 mA
0.8
0.77
V IOL = 14 mA
IOL = 14 mA
0.95
IOL = 84 mA
0.9
IOL = 84 mA
60
(Note 5)(Note 7)
55
Ω
30
(Note 5)(Note 7)
35
RP
IIH
IIL
IOZH
IOZL
IOZPU
IOZPD
IOFF
Maximum Pull-Up
B1 - B8, Y9 - Y13,
Resistance
C14 - C17
Minimum Pull-Up
B1 -B8, Y9 - Y13
Resistance
C14 - C17
Maximum Input
A9 - A13, PLHIN,
Current in
HD, DIR, HLHIN
HIGH State
C14 - C17
C14 -C17
Maximum Input
A9 - A13, PLHIN,
Current in
HD, DIR, HLHIN
LOW State
C14 - C17
C14 - C17
Maximum Output
A1 - A8
Disable Current
B1 - B8
(HIGH)
B1 - B8
Maximum
A1 - A8
Output Disable
B1 - B8
Current (LOW)
B1 - B8
Maximum Power-Up Y9 - Y13
Disable Current
B1 - B8
Maximum Power-Down Y9 - Y13
Disable Current
B1 - B8
Power Down
B1 - B8, Y9 - Y13,
Output Leakage
PLH
3.3
3.3
3.3
5.0
3.3
3.3
3.3
5.0
3.6
3.6
3.6
3.6
3.6
5.5
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
3.6
0 to 1.5
(Note 8)
0 to 1.5
(Note 8)
3.6
5.5
3.6
3.6
5.5
3.6
3.6
5.5
0 to 1.5
(Note 8)
0 to 1.5
(Note 8)
0.0
0.0
1650
1650
1150
1150
1.0
50.0
100
−1.0
−3.5
−5.0
20
50
100
−20
−3.5
−5.0
350
−5
350
−5
100
1650
1650
1150
1150
1.0
50.0
100
−1.0
−3.5
−5.0
20
50
100
−20
−3.5
−5.0
350
−5
350
−5
100
Ω
Ω
VI = 3.6V
µA
VI = 3.6V
VI = 5.5V
µA VI = 0.0V
mA VI = 0.0V
VO = 3.6V
µA VO = 3.6V
VO = 5.5V
µA
mA VO = 0.0V
µA VO = 5.5V
mA VO = 0.0V
µA VO = 5.5V
mA VO = 0.0V
µA VO = 5.5V
IOFF
Power Down
Input Leakage
C14–C17, HLHIN
0.0
0.0
100
100
µA VI = 5.5V
IOFF—ICC Power Down
Leakage to VCC
IOFF—ICC2 Power Down Leakage
to VCC—Cable
ICC
Maximum Supply
Current
0.0
0.0
250
0.0
0.0
250
3.6
3.6
45
3.6
5.5
70
Note 5: Output impedance is measured with the output active LOW and active HIGH (HD = HIGH).
250
µA (Note 6)
250
µA (Note 6)
45
mA VI = VCC or GND
70
mA VI = VCC or GND
Note 6: Power-down leakage to VCC or VCC—Cable is tested by simultaneously forcing all pins on the cable-side (B1–B8, Y9–Y13, PLH, C14–C17 and HLHIN)
to 5.5V and measuring the resulting ICC or ICC—Cable.
Note 7: This parameter is guaranteed but not tested, characterized only.
Note 8: Connect all VCC pins and VCC-Cable pins when forcing voltage applied, DIR = HD = 0V.
5
www.fairchildsemi.com