The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
Assembling Procedure
Male contact
Pin contact housing
Low-numbered side
Wire
about 3.5mm
Low-numbered side
Female contact
Crimped state
After assembling, pull
the wire slightly and
make sure if the con-
tact is mounted as
Socket contact housing shown above.
Procedure for Contact Extraction
In case of extracting a contact from the housing due to
insertion error or circuit change, follow the steps as shown below.
Fig. 1
Extraction
Fig. 2
Shell
1 Hold the Contact Extractor as shown in Fig. 1, plac-
ing the tip of the Extractor on the tip of a contact,
then insert it between the contact and the housing.
2. When the tip of the Extractor comes into contact
with a stepped part in the housing, the spring will
come off from the stepped part with a snap which
can be felt. Then, extract the contact by pulling the
wire.
0. (Caution: Pushing the tip of the extractor forcibly
before the spring has come off from the stepped
part may damage the contact).
3. Above Fig. 1 and Fig. 2 show how to extract a con-
tact from socket housing. The same procedure
can be employed to extract a contact from pin
housing.
116