DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TDA3616T/N1,112 View Datasheet(PDF) - NXP Semiconductors.

Part Name
Description
Manufacturer
TDA3616T/N1,112
NXP
NXP Semiconductors. NXP
TDA3616T/N1,112 Datasheet PDF : 20 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Philips Semiconductors
Multiple voltage regulator with battery
detection
Objective specification
TDA3616
SYMBOL
PARAMETER
CONDITIONS
MIN. TYP. MAX. UNIT
Regulator (IREG = 5 mA; unless otherwise specified)
Vo
output voltage
0.5 mA IREG 150 mA;
7 V VP 18 V; Tamb = 25 °C
0.5 mA IREG 150 mA;
7 V VP 18 V
IREG = 30 mA; 18 V VP 50 V;
load dump
4.8 5.0
4.75 5.0
4.75 5.0
Io
VLN
VL
SVRR
Vdrop
output current
VP > 25 V; load dump
line voltage regulation
7 V VP 18 V
3
load voltage regulation
0.5 mA IREG 150 mA;
Tamb = 25 °C
0.5 mA IREG 150 mA
supply voltage ripple rejection fi = 200 Hz; Vi = 2 V (p-p); Io = 5 mA 55
60
drop-out voltage
IREG = 150 mA; VP = 5 V;
Tamb = 25 °C; note 8
0.6
IREG = 150 mA; VP = 5.5 V; note 8
0.9
Il
current limit
Isc
short-circuit current
VREG > 4.5 V; VP > 10 V; note 9
RL(REG) 0.5 ; Tamb = 25 °C;
note 10
0.25 0.6
40
80
5.2 V
5.25 V
5.25 V
100 mA
50
mV
70
mV
85
mV
dB
1.0 V
1.2 V
1
A
mA
Backup switch
IDC
DC continuous current
Ir
reverse current
VBU > 5 V; note 11
VP = 0 V; VBU = 12.4 V
0.1 0.2
A
200 µA
Notes
1. Minimum operating voltage, only if VP has exceeded 7.5 V.
2. The quiescent current is measured in standby mode. Therefore, the battery input is connected to a low voltage
source and RL(REG) = .
3. The voltage of the regulator sinks as a result of a supply voltage drop.
4. Only one band gap circuit is used as a reference for both regulator and Schmitt trigger for reset. Due to this a tracking
exists between the reset Schmitt trigger levels and the output voltage of the regulator.
5. The temperature coefficient of the internal resistor is 0.2%/K.
6.
The delay time can be calculated with the following formula:
td
=
Rpu(int)
×
Cd
×
ln
(---V----R----EV---G-R----E---G--V----t--h--r---)
7. The battery output voltage will be equal or less than the output voltage of the regulator.
8. The drop-out voltage of the regulator is measured between VP and VREG.
9. At current limit, Il is held constant (behaviour according to dashed line in Fig.5).
10. The foldback current protection limits the dissipated power at short-circuit (see Fig.5).
11. The backup switch can deliver an additional current of 100 mA, guaranteed when the regulator is loaded with nominal
loads (IREG 150 mA).
2000 Jan 14
8

Share Link: 