Figure 4-2. Sleep Command – CRC Enabled
Host (Sends on MOSI)
Device (Responds on MISO)
Command: 0x05
Response: 0x55 (Idle” – Fresh Command)
Simultaneous
Transmission
Command CRC: 0x3F
Response: 0x3F (Expected Command CRC)
4.1.5
When the “Send Setups” command is received, the QT1110 stops measurement of QTouch
sensors and waits for 42 bytes of data to be sent. Only when all 42 bytes have been received
(and the CRC byte, if CRC is enabled), the QT1110 applies all the settings to RAM and resumes
measurement. In this case, if CRC is enabled, the CRC byte is calculated for all the data sent by
the host, including the command byte 0x01.
Control Commands are specified in detail in Section 5 on page 22.
Report Requests
Report Requests are sent by the Host to instruct the QT1110 to return status information. The
host sends the appropiate “Report Request” command, then transmits Null bytes on MOSI while
the QT1110 returns the report data on MISO.
Figure 4-3. All Keys Report – CRC Disabled
Host (Sends on MOSI)
Device (Responds on MISO)
Command: 0xC1
Response: 0x55 (Idle” – Fresh Command)
Simultaneous
Transmission
Null: 0x00
Key Status Report Byte 0
Null: 0x00
Key Status Report Byte 1
12 AT42QT1110-MU/AT42QT1110-AU