C-Series Circuit Breaker - General Specifications | 3
Electrical Tables
Table A: Lists UL Recognized & CSA Accepted configurations and performance capabilities as a component supplementary protector
Circuit
Configuration
Series
Dual Coil
Shunt
Relay
Switch Only
Max.
Rating
32
48
65
80
125
125/250
250
125
150
125/250
250
277
480/277
480
80
125
125/250
250
277
80
277
250
480/277
480
80
277
250
65
80
125
125/250
250
277
480/277
C-SERIES TABLE A: Component Supplementary Protectors
Voltage
Current Rating
Short Circuit
Capacity (Amps)
Application Codes
Full
Frequency Phase Load
Amps
General
Purpose
Amps
UL / CSA
With Without
Backup Backup
Fuse Fuse
UL
CSA
Construction Notes
DC
DC
--- 0.02 - 100 ---
--- 110 - 150
---
---
---
5,000
5,000
TC1, OL1, U2
TC1, OL1, U2
---
---
DC
---
0.02 - 70
---
-
71 - 100
---
5,000
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
---
---
DC
0.02 - 70
---
---
---
71 - 100
---
7,500
TC1, 2, OL1, U1 TC1, 2, OL1, U1
TC1, 2, OL0, U1 TC1, 2, OL0, U1
0.02 - 70
---
---
71 - 100
10,000
TC1, 2, OL1, U1
TC1, 2, OL0, U1
TC1, 2, OL1, U1
TC1, 2, OL0, U1
---
---
Must have Agency "L"
DC
--- 0.02 - 50
---
---
5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
Must have Agency "L"
DC
--- 0.02 - 50
---
---
5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
Must have Agency "L"
DC
--- 0.02 - 50
---
---
5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1 Must have Agency "L". 250 volts requires 2 pole
50 / 60
---
1 0.02 - 100
---
3,000 TC1, OL1, U2 TC1, OL1, U2
---
5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
Per pole rating
Must have Agency "L"
80 - 100
DC
---
---
101 - 175 ---
5,000 TC1, 2, OL0, U3
---
Must have Agency "L"
Must have Agency "L" parallel pole
0.02 - 100
3,500 TC1, OL1, U2 TC1, OL1, U2
---
50 / 60
1
0.02 - 50
51 - 100
---
---
3,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
1,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
2 or 3 poles breaking single phase
2 or 3 poles breaking single phase
0.02 - 100
5,000 TC1, 2, OL1, U2 TC1, 2, OL1, U2 2 or 3 poles breaking single phase. Agency "L"
0.02 - 50
1 0.02 - 100 ---
3,500 TC1, 2, OL1, U2 TC1, 2, OL1, U2
---
5,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
Per pole rating
Must have Agency "L"
51 - 70
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
---
50 / 60
---
0.02 - 100 ---
3,000 TC1, 2, OL0, U2 TC1, 2, OL0, U2
---
3 0.02 - 70
---
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
3 poles breaking 3 phase
---
0.02 - 90 ---
5,000 TC1, 2, OL0, U1 TC1, 2, OL0, U1
Must have Agency "L"
50 / 60
1 0.02 - 50
---
5,000
--
TC1, 2, OL1, C1 TC1, 2, OL1, C1
---
50 / 60
3
0.02 - 30
---
---
5,000
--
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
3 poles breaking 3 phase
---
50 / 60
1
0.02 - 30
---
---
5,000
--
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
2 poles breaking 1 phase
---
DC
--- 0.02 - 50
---
---
7,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
---
50 / 60
1 0.02 - 50
---
---
3,000 TC1, OL1, U2 TC1, OL1, U2
Per pole rating
50 / 60
1 0.02 - 50
---
---
3,500 TC1, OL1, U2 TC1, OL1, U2
3,000 TC1, 2, OL1, U1 TC1, 2, OL1, U1
2 or 3 poles breaking single phase
2 or 3 poles breaking single phase
1
---
3,500 TC1, OL1, U2 TC1, OL1, U2
---
50 / 60
3 0.02 - 50
---
---
5,000
3,000
---
TC1, OL0, U2 TC1, OL0, U2
TC1, 2, OL1, C1 TC1, 2, OL1, C1
Per pole rating
---
50 / 60
1 0.02 - 50
---
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
3 poles breaking 3 phase
DC
--- 0.02 - 50
---
---
7,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
---
50 / 60
1 0.02 - 50
---
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
---
50 / 60
3 0.02 - 50
---
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
3 poles breaking 3 phase
50 / 60
3
0.02 - 30
---
---
31 - 50
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
3 poles breaking 3 phase
---
50 / 60
1
0.02 - 30
---
---
31 - 50
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
TC1, 2, OL0, C1 TC1, 2, OL0, C1
2 poles breaking 1 phase
---
DC
--- 0.02 - 50
---
---
7,500 TC1, 2, OL1, U1 TC1, 2, OL1, U1
---
50 / 60
1 0.02 - 50
---
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
---
50 / 60
3 0.02 - 50
---
5,000
---
TC1, 2, OL1, C1 TC1, 2, OL1, C1
3 poles breaking 3 phase
71 - 100
DC
---
---
---
---
---
---
---
---
71 - 100
DC
---
---
---
---
---
---
---
---
50 / 60
1 0.02 - 100 ---
---
---
---
---
---
50 / 60
1 0.02 - 100 ---
---
---
---
---
2 or 3 poles breaking single phase
1 0.02 - 100
---
50 / 60
3 0.02 - 70
---
---
---
---
---
---
50 / 60
1 0.02 - 50
---
---
---
---
---
---
0.02 - 30
---
50 / 60
3
---
31 - 50
---
---
---
---
3 poles breaking 3 phase
---
Notes:
1. Requires branch circuit backup with a UL LISTED Type K5 or RK5 fuse rated 15A minimum and no more than 4 times full load amps not to exceed 125A for 50 Amp or less