Electrical Characteristics (Cont’d): (TA = +25°C, V+ = 12V unless otherwise specified)
Parameter
Symbol
Test Conditions
Min Typ Max Unit
Dynamic Characteristics (eIN = 0.4VP–P Sine Wave)
Oscillator Center Frequency
fO Set R for fO = 3.579545 ±5Hz
Oscillator Frequency Deviation
fO1
Oscillator Frequency Deviation
|∆fO| V+ = 12V ±1V
Oscillator Pull–In Range, High Side
Osc. must pull–in and lock to eIN at:
fIN = 3.579745MHz
Oscillator Pull–In Range, Low Side
Osc. must pull–in and lock to eIN at:
fIN = 3.579345MHz
Dynamic ACC
Measure Pin15 to Pin16, Record value
(V1)
–
–
–400 –
–
–
200 –
– Hz
400 Hz
175 Hz
– Hz
–200 –
– Hz
–75 – 75 mV
ACC Control
∆ACC Control
Measure Pin15 to Pin16,
fIN = 3.579545MHz
Limits for ∆ACC Control = V2 – V1
Record Value (V2) mV
120 – 250
Dynamic APC
Tap of R to GND
1
– 12 V
Pin Connection Diagram
Hue Control 1
OSC Output 2
OSC Output 3
Horiz Key Pulse Input 4
GND 5
OSC Input 6
OSC Feedback Loop 7
OSC Feedback Loop 8
16 ACC Output
15 ACC Output
14 ACC Input
13 APC Input
12 APC Output
11 APC Output
10 V (+)
9 N.C.
16
9
1
8
.870 (22.0)
Max
.200 (5.08)
Max
.260
(6.6)
Max
.100 (2.54)
.700 (17.78)
.099 (2.5) Min