TOSHIBA Bi-CMOS Integrated
Circuit Silicon Monolithic
TB62713N/F
Brightness Control
Brightness is controlled by controlling the “on time” duty cycle. The device allows for 16 bright-
ness as illustrated in list 3 with 0/16 as the dimmest setting (not illuminated) to 15/16 as the
brightest setting. The duty cycle control register is addressed with a 20 Hex command at
D15~D8 and the appropriate data per list 3 at D3~D0. D7~D4 are not recognized by the duty
cycle register. The initial state, upon power up is 15/16, or full brightness.
REGISTER DATA
DUTY CYCLE D15~D8 D7~D4 D3 D2 D1 D0 Hex Code
0/16
20H
—
0
0
0
0
20X0H
1/16
20H
—
0
0
0
1
20X1H
2/16
20H
—
0
0
1
0
20X2H
3/16
20H
—
00
1
1
20X3H
4/16
20H
—
0
10
0
20X4H
5/16
20H
—
0
10
1
20X5H
6/16
20H
—
0
1
1
0
20X6H
7/16
20H
—
0
1
1
1
20X7H
8/16
20H
—
10
0
0
20X8H
9/16
20H
—
1
0
0
1
20X9H
10/16
20H
—
10
1
0
20XAH
11/16
20H
—
10
1
1
20XBH
12/16
20H
—
1
1
0
0
20XCH
13/16
20H
—
1
1
0
1
20XDH
14/16
20H
—
1
1
1
0
20XEH
15/16
20H
—
1
1
1
1
20XFH
INITIAL
STATE
⇐
“x” indicates that data is required in this field to execute the function. “-” indicates that data in
this field is not required and not recognized.
marktech
optoelectronics
120 Broadway • Menands, New York 12204
Toll Free: (800) 98-4LEDS • Fax: (518) 432-7454
For up-to-date product info visit our web site at www.marktechopto.com
All specifications subject to change.
617