DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACT8846(2013) View Datasheet(PDF) - Active-Semi, Inc

Part Name
Description
Manufacturer
ACT8846
(Rev.:2013)
ACTIVE-SEMI
Active-Semi, Inc ACTIVE-SEMI
ACT8846 Datasheet PDF : 40 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
ACT8846
Rev 1, 15-May-13
REGISTER AND BIT DESCRIPTIONS CONT’D
BLOCK ADDRESS BIT
REG6 0x59 [6:3]
REG6 0x59 [2]
REG6
REG6
REG7
REG7
REG7
REG7
0x59 [1]
0x59 [0]
0x60 [7:6]
0x60 [5:0]
0x61 [7]
0x61 [6:3]
REG7 0x61 [2]
REG7
REG7
REG8
REG8
REG8
REG8
0x61 [1]
0x61 [0]
0x68 [7:6]
0x68 [5:0]
0x69 [7]
0x69 [6:3]
REG8 0x69 [2]
REG8
REG8
REG9
REG9
REG9
REG9
0x69 [1]
0x69 [0]
0x70 [7:6]
0x70 [5:0]
0x71 [7]
0x71 [6:3]
REG9 0x71 [2]
REG9 0x71 [1]
REG9 0x71 [0]
REG10 0x80 [7:6]
NAME
-
DIS
nFLTMSK
OK
-
VSET
ON
-
DIS
nFLTMSK
OK
-
VSET
ON
-
DIS
nFLTMSK
OK
-
VSET
ON
-
DIS
nFLTMSK
OK
-
ACCESS
DESCRIPTION
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kresistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kresistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kresistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
R/W
Output Voltage Selection. See the Output Voltage Programming
section for more information.
R/W
Regulator Enable Bit. Set bit to 1 to enable the regulator, clear
bit to 0 to disable the regulator.
R Reserved.
Output Discharge Control. When activated, LDO output is
R/W
discharged to GA through 1.5kresistor when in shutdown. Set
bit to 1 to enable output voltage discharge in shutdown, clear bit
to 0 to disable this function.
R/W
Regulator Fault Mask Control. Set bit to 1 enable fault-interrupts,
clear bit to 0 to disable fault-interrupts.
R
Regulator Power-OK Status. Value is 1 when output voltage
exceeds the power-OK threshold, value is 0 otherwise.
R Reserved.
Innovative PowerTM
- 13 -
Active-Semi ProprietaryFor Authorized Recipients and Customers
ActivePMUTM is a trademark of Active-Semi.
I2CTM is a trademark of NXP.
www.active-semi.com
Copyright © 2013 Active-Semi, Inc.

Share Link: 