8XC51SL LOW VOLTAGE 8XC51SL
PROGRAMMING THE OTP
The part must be running with a 4 MHz to 6 MHz
oscillator The address of a location to be pro-
grammed is applied to address lines while the code
byte to be programmed in that location is applied to
data lines Control and program signals must be held
at the levels indicated in Table 4 Normally EAL VPP
is held at a logic high until just before RCL PROGL
is to be pulsed The EAL VPP is raised to VPP
RCL PROGL is pulsed low and then EAL VPP is re-
turned to VCC (also refer to timing diagrams) Also
the LOADREN signal must be grounded when pro-
gramming or verifying
NOTE
Exceeding the VPP maximum for any amount of
time could damage the device permanently The
VPP source must be well regulated and free of
glitches
DEFINITION OF TERMS
ADDRESS LINES P10 – P17 P20– P25 respective-
ly for A0– A13
DATA LINES
ADB0– 7
CONTROL SIGNALS RST GATEA20 P26 P27
P32 P36 P37
PROGRAM SIGNALS RCL PROGL EAL VPP
PROGRAMMING ALGORITHM
Refer to Table 4 and Figures 8 and 9 for address
data and control signals setup To program the
87C51SL the following sequence must be exercised
1 Input the valid address on the address lines
2 Input the appropriate data byte on the data lines
3 Activate the correct combination of control sig-
nals
4 Raise EAL VPP from VCC to 12 75V g0 25V
5 Pulse RCL PROGL 5 times
Repeat 1 through 5 changing the address and data
for the entire array or until the end of the object file is
reached
Table 4 OTP Programming Modes
Mode
RST
GATEA20
RCL
PROGL
EAL VPP
P26
P27
P32
P36
P37
Program Code Data
H
L
12 75V
L
H
H
H
H
Verify Code Data
H
L
H
H
L
L
L
H
H
Read Signature Byte H
L
H
H
L
L
L
L
L
Note that in the above table to program code data
on the Low Voltage 87C51SL VCC must be raised to
5V g10% In addition all address lines data lines
and control signals being driven to a ‘‘High’’ level
must be raised to 5V g10% The RCL PROGL sig-
nal must pulse between 0V and 5V g10%
To verify code data or read the signature bytes of
the Low Voltage 87C51SL VCC must be set to 3 3V
g0 3V In addition all address lines and control sig-
nals being driven to a ‘‘High’’ level must be raised to
3 3V g0 3V
For the standard (5V version) of the 87C51SL VCC
must always be at 5V g10% and all ‘‘High’’ volt-
ages must meet the DC specs indicated in the DC
Characteristics section of this document