Electrical Characteristics
Parameter and Conditions
at Tj =-40...+150°C, Vbb = 12 V unless otherwise specified
PROFET® ITS428L2
Symbol
Values
Unit
min typ max
Load Switching Capabilities and Characteristics
On-state resistance (pin 3 to 5)
IL = 2 A; VBB ≥ 7V
see diagram, page 10
Tj=25 °C: RON
Tj=150 °C:
Nominal load current, (pin 3 to 5)
ISO 10483-1, 6.7:VON=0.5V, TC=85°C
Output current (pin 5) while GND disconnected or
GND pulled up6) , Vbb=30 V, VIN= 0,
see diagram page 8
Turn-on time
IN
to 90% VOUT:
Turn-off time
IN
to 10% VOUT:
RL = 12 Ω,
Slew rate on
10 to 30% VOUT, RL = 12 Ω,
Slew rate off
70 to 40% VOUT, RL = 12 Ω,
IL(ISO)
IL(GNDhigh)
ton
toff
dV /dton
-dV/dtoff
-- 50 60 mΩ
100 120
5.8 7.0
--
--
-- A
2 mA
30 100 200 µs
30 100 200
0.1
--
1 V/µs
0.1
--
1 V/µs
Operating Parameters
Operating voltage
Overvoltage protection7)
Ibb=40 mA
Standby current (pin 3) 8)
VIN=0; see diagram on page 10
Tj =-40
Tj =+25...+150°C:
Tj =-40°C:
Tj =25...+150°C:
Tj=-40...+25°C:
Tj= 150°C:
Off-State output current (included in Ibb(off))
VIN=0
Operating current 9), VIN=5 V
Vbb(on)
Vbb(AZ)
Ibb(off)
IL(off)
IGND
4.75
-- 41 V
-- 43
41
--
-- V
43 47 52
--
5
9 µA
--
-- 25
--
1 10 µA
-- 0.8 1.5 mA
6) not subject to production test, specified by design
7) Supply voltages higher than Vbb(AZ) require an external current limit for the GND and status pins (a 150Ω
resistor for the GND connection is recommended. See also VON(CL) in table of protection functions and
circuit diagram page 8.
8) Measured with load
9) Add IST, if IST > 0, add IIN, if VIN>5.5 V
Infineon Technologies AG
Page 4