DIGITAL FILTER CHARACTERISTICS1
Passband Ripple (0 kHz to 20 kHz)
Transition Band2
Stopband Attenuation
Group Delay (LR_I = 50 kHz)
POWER (FSIN = 48 kHz, FSOUT = 44.1 kHz)
Supplies
Voltage, VDD
Operational Current, IDD (VDD = +5.0 V)
Operational Current, IDD (VDD = +3.0 V)1
Power-Down Current, IDD (VDD = +5.0 V)
Power-Down Current, IDD (VDD = +3.0 V)1
Dissipation1
Operation (VDD = +5.0 V)
Operation (VDD = +3.0 V)
Power-Down (VDD = +5.0 V)
Power-Down (VDD = +3.0 V)
AD1893
Min
Max
Units
0.01
dB
4.1
kHz
110
dB
700
3000
µs
Min
Typ
Max
Units
2.7
5.5
V
30
40
mA
15
20
mA
1.5
2.5
mA
0.5
1.0
mA
150
200
mW
45
60
mW
7.5
12.5
mW
1.5
3.0
mW
TEMPERATURE RANGE
Specifications Guaranteed
Operational Guaranteed
Storage
Min
Max
0
+70
–40
+85
–60
+100
Units
°C
°C
°C
ABSOLUTE MAXIMUM RATINGS3
Min
Max
Units
VDD to GND
DC Input Voltage
Latch-Up Trigger Current
Soldering
–0.3
–0.3
–1000
7.0
V
VDD + 0.3
V
+1000
mA
+300
°C
10
sec
NOTES
1Guaranteed, Not Tested
2Valid only when FSOUT ≥ FSIN (i.e., upsampling), FSIN = 44.1 kHz.
3Stresses greater than those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of
the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating
conditions for extended periods may affect device reliability.
Specifications subject to change without notice.
ORDERING GUIDE
Model
AD1893JN
AD1893JST
Temperature Range
0°C to +70°C
0°C to +70°C
Package Descriptions
Plastic DIP
LQFP
Package Options
N-28
ST-44
CAUTION
ESD (electrostatic discharge) sensitive device. Electrostatic charges as high as 4000 V readily
accumulate on the human body and test equipment and can discharge without detection.
Although the AD1893 features proprietary ESD protection circuitry, permanent damage may
occur on devices subjected to high energy electrostatic discharges. Therefore, proper ESD
precautions are recommended to avoid performance degradation or loss of functionality.
WARNING!
ESD SENSITIVE DEVICE