µPD784031Y
6. CPU ARCHITECTURE
6.1 Memory Space
A memory space of 1 Mbytes can be accessed. Mapping of the internal data area (special function registers and internal
RAM) can be specified the LOCATION instruction. The LOCATION instruction must be always executed after reset
cancellation, and must not be used more than once.
(1) When LOCATION 0 instruction is executed
The internal data area is mapped in 0F700H to 0FFFFH.
(2) When LOCATION 0FH instruction is executed
The internal data area is mapped in FF700H to FFFFFH.
17