Absolute Maximum Ratings
Parameter
Symbol
Storage Temperature
TS
Operating Temperature
TA
Lead Solder Temp
Supply Voltage
VDD
ESD
Input Voltage
VIN
Input Voltage
VIN
Minimum
-40
-15
-0.5
-0.5
-0.5
Maximum
85
55
260
5.5
2
VDD+ 0.5
3.6
Units
°C
°C
°C
V
KV
V
V
Notes
For 10 seconds, 1.6 mm below seating plane
All pins, human body model MIL 883 Method 3015
SDIO, CLK, LED_CNTL
OSC_IN, OSC_OUT, REFA
Recommended Operating Conditions
Parameter
Symbol
Operating Temperature
TA
Power Supply Voltage
VDD
Power Supply Rise Time
VRT
Supply Noise
VN
Clock Frequency
Serial Port Clock Frequency
Resonator Impedance
Distance from Lens Reference
Plane to Surface
Speed
Acceleration
Light Level onto IC
fCLK
SCLK
XRES
Z
S
A
IRRINC
SDIO Read Hold Time
tHOLD
SDIO Serial Write-write Time
tSWW
SDIO Serial Write-read Time
tSWR
SDIO Serial Read-write Time
tSRW
SDIO Serial Read-read Time
tSRR
Data Delay after PD deactivated tCOMPUTE
SDIO Write Setup Time
Frame Rate
tSETUP
FR
Minimum
0
4.1
Typical
5.0
23.0
24.0
2.3
2.4
0
80
100
100
100
100
250
250
3.1
60
Maximum
40
5.5
100
100
25.0
fCLK/12
55
2.5
12
0.25
25,000
30,000
1500
Units Notes
°C
Volts
ms
mV
MHz
MHz
mm
in/sec
g
mW/m2
µs
µs
µs
ns
ns
ms
ns
frames/s
Register values retained for voltage
transients below 4.10V but greater
than 3.9V
Peak to peak within 0-100 MHz
bandwidth
Set by ceramic resonator
Results in ±0.2 mm DOF
(See Figure 9)
@ frame rate = 1500 fps
@ frame rate = 1500 fps
λ = 639 nm
λ = 875 nm
Hold time for valid data
(Refer to Figure 22)
Time between two write commands
(Refer to Figure 25)
Time between write and read
operation (Refer to Figure 26)
Time between read and write
operation (Refer to Figure 27)
Time between two read commands
(Refer to Figure 26)
After tCOMPUTE, all registers contain
data from first image after wakeup
from Power-Down mode. Note that an
additional 75 frames for AGC
stabilization may be required if mouse
movement occurred while Power
Down. (Refer to Figure 10)
Data valid time before the rising of
SCLK (Refer to Figure 20)