MF608B
4.5.2 . Return loss :
Return loss measures the amount of lost energy due to reflection resulted from
impedance mismatching at the interface. Return loss is essentially defined as the ratio
of the incident power upon a given transmission system to the reflective power caused
by impedance mismatch with respect to reference impedance at the interface between
source and device. Return loss figure is a function of the impedance of the circuit
involved and therefore frequency dependent. These impedance must be closely
maintained in order to reduce the possibility of undesirable reflection and echoes
which results from long distance circuit of the telephone user and may destroy the data
being sent. To perform the return loss test , open ,short and load calibration must be
done prior measurement while the LCZ impedance analyzer being selected in
impedance mode. Return loss is general expressed in decibels.
General return loss equation is listed: Return loss = 20 log ZL + ZM / ZL - ZMdB
Where ZL = the reference impedance ZM = the measured impedance
The test setup is shown in drawing below: