M63022FP
SPINDLE MOTOR AND 5CH ACTUATOR DRIVER
ELECTRICAL CHARACTERISTICS (Ta=25˚C, 5VCC=VM3=5V,VM1=VM2=12V unless otherwise noted.)(cont.)
Symbol
Loading
Parameter
Vdyc3-1 Dynamic range of output
Vdyc3-2 Dynamic range of output
Vin3
Control voltage input range 3
Gvo3
Control gain 3
Voff1
Output offset voltage
Focus/Tracking
Vdyc4 Control voltage input range 4
Vin4
Control gain 4
Gvo4 Output offset voltage
Voff2
Output offset voltage
Test conditions
Io=0.5[A]
VM3=5[V]
VM1=12[V]
VM3=12[V]
R=5.4[], VM3=4.75V,VM1=12V
LOIN+
(LO+) - (LO-)
(LOIN+) - (REF)
(LO+) - (LO-) at LOIN+=REF=1.65V
Io=0.5[A],VM1=12[V]
FOIN,TOIN
(FO+)-(FO-)
(TO+)-(TO-)
FOIN-REF
TOIN-REF
(FO+)-(FO-) at REF=FOIN=1.65V
(TO+)-(TO-) at REF=TOIN=1.65V
Limits
Min. Min. Max. Unit
3.9
4.2
6.9
7.6
3.3
3.5
0
V
V
5
V
16.7 18.1 19.3 dB
-50
0 +50 mV
3.8 4.2
0
V
5
V
20.2 21.6 22.8 dB
-47
0 +47 mV
Note 2. This IC need condenser between each supply lines and GND for stoped Oscillation.
THERMAL CHARACTERISTICS
Symbol
Parameter
Function start temperature of ic Function stop temperature of ic
Min. Typ. Max. Min. Typ. Max. Unit
TSD
Thermal shut down
160
130
˚C
Note 3. This TSD function start temperature doesn't show the guaranteed max. temperature of the devices.
The guranteed max. temperature is Tj max. which is shown in "9. ABSOLUTE MAXIMUM RATING". The TSD function is a thermal protection in case
the temperature of the devices goes up above Tjmax because of wrong use.
And these TSD temperature are the target temperatures for circuit design, not the guranteed temperatures.
(The TSD function of all the devices is not checked by a test in high temperature.)
q Standby function
SELECT2
SELECT1
Logic control
MU1
H
L/Open
Loading
On
Off
Slide1
On
Off
Drive channel
Slide2 Focus
On
On
Off
Off
This IC has MUTE terminal (MU1).
It is possible to control ON / OFF of the channel by external logic
inputs.
In case of SELECT1, the bias of all circuit becomes OFF.
Therefore, this mode is available in order to reduce the power
dissipation when the waiting mode.
In case of SELECT2,the bias of all channel becomes ON.
q Brake select function
BRS
Hi
L/Open
SPIN<REF
Reverse
Short
REF<SPIN
Forward
Forward
This IC has BRS terminal (BRS).
It is possible for a braking timiming of Spindle drive to select which the
short brake or the reverse brake by BRS.
It shuould select the short brake in case of high speed system and
please change to the reverse brake when the rotation speed becomes
enough low. It is available when the SPIN voltage is low than the
reference voltage.
Tracking
On
Off
Spindle
On
Off

Share Link: 