Electrical Characteristics (Cont’d): (TA = +25°C unless otherwise specified)
Test Conditions
Switch Numbers
S1 S2 S3 S4 S5 S6 S7 S8 S9 S10 S11
Parameter
Switch Positions
For Characteristic Measurements
Dynamic Characteristics (Bias Voltage = 5.8V)
Min Typ Max Unit
Wide–Band Gain (Note 2)
1 1 1 2 1 2 1 1 1 2 1 6.0 8.3 11.0 dB
Contrast Gain Reduction (Note 3) 1 1 1 2 1 2 1 1 2 2 1 27 30 – dB
Peaking Gain (Note 2)
1 1 2 2 1 2 1 1 1 2 1 15.0 18.4 22.0 dB
Peaking Gain Reduction (Note 4) 1 1 2 2 1 2 1 1 1 2 1 16 18 – dB
Max. Intermodulation Distortion
2V (Note 5)
1 – 1 1 1 2 – 2 1 2 1 – 20 – %
3V (Note 6)
1 – 1 1 1 2 – 2 1 2 1 – 40 – %
Note 2. Set 50kHz generator for 100mVP–P Adjust R1 Peaking Control for minimum setting. Measure
wide–band gain at Pin7.
Note 3. Set 50kHz generator for 100mVP–P. Adjust R1 for minimum setting. Measure contrast gain
reduction at Pin7.
Note 4. Set 50kHz generator for 100mVP–P. Adjust R1 for maximum setting. Measure peaking gain
reduction at Pin7.
Note 5. Adjust R1 for minimum setting. With S2 at switch position 1 and S7 at switch position 3, set
50kHz generator for 2VP–P. Then with S2 at switch position 2, set 1MHz generator for
100mVP–P. Then with S7 at switch position 2, measure downward modulation of the 1MHz
signal due to the 50kHz signal.
Note 6. Repeat step 5 except that the 50kHz generator must be set at 3VP–P.
14
8
Pin Connection Diagram
Video Input 1
Peaking Input 2
Peaking Input 3
Video Output 4
Substrate GND 5
Clamp Inhibit 6
Clamped Video Out 7
14 N.C.
13
Shunt Regulator
and Bypass
12 Clamp Inhibit Input
11 Peaking Control
10 Contrast Control
9 Blanking Input
8 Brightness Control
1
7
.785 (19.95)
Max
.200 (5.08)
Max
.300
(7.62)
.100 (2.45)
.600 (15.24)
.099 (2.5) Min