CRITERIA FOR DEVICE QUALIFICATION
All Allegro sensors are subjected to stringent qualification requirements prior to being released to production. To
become qualified, except for the destructive ESD tests, no failures are permitted.
Qualification Test
Test Method and
Test Conditions
Test Length
Samples
Per Lot
Comments
Temperature Humidity
Bias Life
Bias Life
(Surge Operating Life)
Autoclave, Unbiased
High-Temperature
(Bake) Storage Life
Temperature Cycle
JESD22-A101,
TA = 85°C, RH = 85%
JESD22-A108,
TA = 150°C, TJ = 165°C
JESD22-A108,
TA = 175°C, TJ = 190°C
JESD22-A102,
TA = 121°C, 15 psig
JESD22-A103,
TA = 170°C
JESD22-A104
1000 hrs
48
1000 hrs
48
168 hrs
48
96 hrs
48
1000 hrs
48
1000 cycles
48
Device biased for
minimum power
-55°C to +150°C
ESD,
Human Body Model
CDF-AEC-Q100-002
Pre/Post
Reading
3 per
test
Test to failure
Pin 3 > 1.5 kV
All leads > 8 kV
APPLICATIONS INFORMATION
Recommended Evaluation Technique. The self-
calibrating feature of the ATS632LSA requires that a
special evaluation technique be used to measure its high-
accuracy performance capabilities. Installation inaccura-
cies are calibrated out at power on; hence, it is extremely
important that the device be re-powered at each air gap
when gathering timing accuracy data.
Self-Calibrating Functions. These subassemblies are
designed to minimize performance variation caused by
the large air gap variations resulting from installation by
self-calibrating at power-on. They are also designed to
minimize performance variation caused by the smaller,
slower air gap changes resulting from temperature
change and gear run-out during continuous operation by
updating the self-calibration periodically (after every 64
output pulses) if necessary. These two functions should
be tested using the following procedure.
1. Set the air gap to the desired value.
2. Power down and then power on the device.
3. Rotate the target at the desired speed.
4. Wait for calibration to complete (16 output pulses to
occur).
5. Monitor output for correct switching and measure
accuracy.
6. Repeat the above for multiple air gaps within the
operating range of the device.
7. This can be repeated over the entire temperature
range.