CXD2460R
3) Output timing characteristics using DSGAT and RST
DSGAT, RST
twRST
0.5VDDa
0.5VDDa
EXP, XCPDM, XCPOB,
PBLK, XSHP, XSHD, XRS,
RG, H1, H2
tpRST
0.5VDDa, b, c, d
H1 and H2 load = 270pF
EXP, XCPDM, PBLK, XSHP, XSHD, XRS and RG load = 10pF (Within the recommended operating conditions)
Symbol
tpRST
twRST
Definition
Time until the above outputs reach the specified value after
the fall of DSGAT and RST
RST and DSGAT pulse width
Min. Typ. Max. Unit
125 ns
10
ns
4) FRI and HRI loading characteristics
FRI, HRI
MCK
0.5VDDa
tsSYNC
thSYNC
0.5VDDa
0.5VDDa
MCK load = 35pF
(Within the recommended operating conditions)
Symbol
Definition
Min. Typ. Max. Unit
tsSYNC
FRI and HRI setup time, activated by the rising edge of MCK
5
ns
thSYNC FRI and HRI hold time, activated by the rising edge of MCK
5
ns
– 10 –