DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

IHB100SC View Datasheet(PDF) - Murata Power Solutions

Part Name
Description
Manufacturer
IHB100SC Datasheet PDF : 4 Pages
1 2 3 4
PARAMETER
Output Power
Set Point Voltage
Output Current, IOUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
IO = IO, Nom
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
CONDITIONS
100 Watts Max
IO Nom
DC to 20MHz*
*
VIN, MinVINVIN, Max
Min Load to Rated Load
50 to 100% Load Step
VOUT, 1% of VOUT, Nom
VIN=NOM, IO=30A
PARAMETER
CONDITIONS
Output Power
Set Point Voltage
Output Current, IOUT
Output Ripple, p-p
Output Adjust Range
Output Temperature Drift
Line Regulation
IO = IO, Nom
Load Regulation
Current Limit Inception
Short-Circuit Current
Transient Response
Peak Deviation
Settling Time
Overvoltage Limit
Efficiency
100 Watts Maximum
IO Nom
DC to 20MHz*
*
VIN, MinVINVIN, Max
Min Load to Rated Load
50 to 100% Load Step
VOUT, 1% of VOUT, Nom
VIN=NOM, IO=20A
*See Application Notes available on the web at www.murata-ps.com
Min
0
3.15
0.05
4.2
83
Min
0
4.60
0.05
6.0
86
Nom
50
3.3
15
100
.02
0.10
0.50
38
30
150
35
84
VOUT
Nom
50
5.1
10
100
.02
0.10
0.5
26.0
20.0
200
35
87
VOUT
Max
100
30.0
200
3.80
.05
1.00
38
250
50
5.0
UNITS
W
V
A
mV
V
%/°C
%
%
A
A
mV
MSec
V
%
Max
UNITS
100
W
V
20
A
150
mV
5.50
V
.05
%/°C
%
1.0
%
A
26.0
A
300
mV
50
MSec
7.0
V
%
THROUGH-HOLE SOLDERING INFORMATION
These devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected
to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this
time and temperature range, the integrity of the device’s plastic body will not be compromised and
internal temperatures within the converter will not exceed 175°C. Care should be taken to control
manual soldering limits identical to that of wave soldering.
IHB100SC REV A (RoHS) 05/2006
3

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]