DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TSOP4130SS1BS12 View Datasheet(PDF) - Vishay Semiconductors

Part Name
Description
Manufacturer
TSOP4130SS1BS12
Vishay
Vishay Semiconductors Vishay
TSOP4130SS1BS12 Datasheet PDF : 8 Pages
1 2 3 4 5 6 7 8
TSOP41..SS1BS12
Vishay Semiconductors
VISHAY
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
f = 38 kHz, Ee = 2 mW/m2
0.1
0.0
0 20 40 60 80 100 120
16914
Burst Length ( number of cycles / burst )
Figure 9. Max. Envelope Duty Cycle vs. Burstlength
0.6
0.5 Sensitivity in dark ambient
0.4
0.3
0.2
0.1
0.0
–30 –15 0 15 30 45 60 75 90
16918
Tamb – Ambient Temperature ( qC )
Figure 10. Sensitivity vs. Ambient Temperature
1.2
1.0
0.8
0.6
0.4
0.2
0.0
750
16919
850
950
1050
l – Wavelength ( nm )
1150
Figure 11. Relative Spectral Sensitivity vs. Wavelength
www.vishay.com
4
0q 10q 20q
30q
40q
1.0
0.9
50q
0.8
60q
70q
0.7
80q
0.6 0.4 0.2 0 0.2 0.4 0.6
96 12223p2
drel – Relative Transmission Distance
Figure 12. Directivity
Suitable Data Format
The circuit of the TSOP41..SS1BS12 is designed in
that way that unexpected output pulses due to noise
or disturbance signals are avoided. A bandpassfilter,
an integrator stage and an automatic gain control are
used to suppress such disturbances.
The distinguishing mark between data signal and dis-
turbance signal are carrier frequency, burst length
and duty cycle.
The data signal should fulfill the following conditions:
• Carrier frequency should be close to center fre-
quency of the bandpass (e.g. 38 kHz).
• Burst length should be 6 cycles/burst or longer.
• After each burst which is between 6 cycles and 70
cycles a gap time of at least 10 cycles is necessary.
• For each burst which is longer than 1.8 ms a corre-
sponding gap time is necessary at some time in the
data stream. This gap time should have at least same
length as the burst.
• Up to 2200 short bursts per second can be received
continuously.
Some examples for suitable data format are: NEC
Code, Toshiba Micom Format, Sharp Code, RC5
Code, RC6 Code, RCMM Code, R-2000 Code,
RECS-80 Code.
When a disturbance signal is applied to the
TSOP41..SS1BS12 it can still receive the data signal.
However the sensitivity is reduced to that level that no
unexpected pulses will occure.
Some examples for such disturbance signals which
are suppressed by the TSOP41..SS1BS12 are:
&bulllet; DC light (e.g. from tungsten bulb or sunlight)
&bulllet; Continuous signal at 38 kHz or at any other
frequency
Document Number 82138
Rev. 2, 15-Oct-2002

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]