DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MB84VA2107 View Datasheet(PDF) - Fujitsu

Part Name
Description
Manufacturer
MB84VA2107 Datasheet PDF : 29 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MB84VA2106-10/MB84VA2107-10
Table 6 Flash Memory Command Definitions
Command
Sequence
Bus
Write
Cycles
Reqโ€™d
First Bus
Write Cycle
Addr. Data
Second Bus
Write Cycle
Addr. Data
Third Bus
Write Cycle
Addr. Data
Fourth Bus
Read/Write
Cycle
Addr. Data
Fifth Bus
Write Cycle
Addr. Data
Sixth Bus
Write Cycle
Addr. Data
Read/Reset
1 XXXH F0H โ€” โ€” โ€” โ€” โ€” โ€” โ€” โ€” โ€” โ€”
Read/Reset
3 555H AAH 2AAH 55H 555H F0H RA RD โ€” โ€” โ€” โ€”
Autoselect
3 555H AAH 2AAH 55H 555H 90H โ€” โ€” โ€” โ€” โ€” โ€”
Program
4 555H AAH 2AAH 55H 555H A0H PA PD โ€” โ€” โ€” โ€”
Chip Erase
6 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H 555H 10H
Sector Erase
6 555H AAH 2AAH 55H 555H 80H 555H AAH 2AAH 55H SA 30H
Sector Erase Suspend
Erase can be suspended during sector erase with Addr. (โ€œHโ€ or โ€œLโ€). Data (B0H)
Sector Erase Resume
Erase can be resumed after suspend with Addr. (โ€œHโ€ or โ€œLโ€). Data (30H)
Set to
Fast Mode
3 555H AAH 2AAH 55H 555H 20H โ€” โ€” โ€” โ€” โ€” โ€”
Fast Program
(Note)
2 XXXH A0H PA PD โ€” โ€” โ€” โ€” โ€” โ€” โ€” โ€”
Reset from Fast
Mode (Note)
2 XXXH 90H XXXH F0H โ€”
โ€”
โ€”โ€”
โ€”
โ€”โ€”โ€”
Extended Sector
Protect
4 XXXH 60H SPA 60H SPA 40H SPA SD โ€”
โ€”
โ€”
โ€”
Address bits A11 to A20 = X = โ€œHโ€ or โ€œLโ€ for all address commands except for Program Address (PA) and Sector
Address (SA).
Bus operations are defined in Table 2.
Both Read/Reset commands are functionally equivalent, resetting the device to the read mode.
RA =Address of the memory location to be read.
PA =Address of the memory location to be programmed. Addresses are latched on the falling edge of
the write pulse.
SA =Address of the sector to be erased. The combination of A20, A19, A18, A17, A16, A15, A14, and A13 will
uniquely select any sector.
RD =Data read from location RA during read operation.
PD =Data to be programmed at location PA.
SPA =Sector address to be protected. Set sector address (SA) and (A6, A1, A0) = (0, 1, 0).
SD =Sector protection verify data. Output 01H at protected sector addresses and output 00H at unprotected
sector addresses.
Note:This command is valid while Fast Mode.
9