Symbol Parameter Conditions
II
ICC
ΔICC
CI
input leakage
current
supply current
additional
supply current
input
capacitance
VI = 5.5 V or GND;
VCC = 0 V to 5.5 V
VI = VCC or GND; IO = 0 A;
VCC = 5.5 V
per input pin; VI = 3.4 V;
other inputs at VCC or GND;
IO = 0 A; VCC = 5.5 V
25 °C
Min Typ Max
-
-
0.1
-
-
1.0
-
-
1.35
-
1.5
10
-40 °C to
+85 °C
Min Max
-
1.0
-
10
-
1.5
-
10
-40 °C to Unit
+125 °C
Min Max
-
2.0 μA
-
40 μA
-
1.5 mA
-
10 pF
11. Dynamic characteristics
Table 8. Dynamic characteristics
GND = 0 V; tr = tf = ≤ 3.0 ns. For test circuit see Fig. 6.
Symbol Parameter Conditions
25 °C
74AHC1G04-Q100
tpd
propagation
delay
CPD
power
dissipation
capacitance
74AHCT1G04-Q100
tpd
propagation
delay
CPD
power
dissipation
capacitance
Min
A to Y; see Fig. 5
[1]
VCC = 3.0 V to 3.6 V; CL = 15 pF [2] -
VCC = 3.0 V to 3.6 V; CL = 50 pF [2] -
VCC = 4.5 V to 5.5 V; CL = 15 pF [3] -
VCC = 4.5 V to 5.5 V; CL = 50 pF [3] -
per buffer; CL = 50 pF; f = 1 MHz;
VI = GND to VCC
[4] -
A to Y; see Fig. 5
[1]
VCC = 4.5 V to 5.5 V; CL = 15 pF [3] -
VCC = 4.5 V to 5.5 V; CL = 50 pF [3] -
per buffer; CL = 50 pF; f = 1 MHz;
VI = GND to VCC
[4] -
Typ Max
4.3 7.1
6.1 10.6
3.1 5.5
4.5 7.5
15 -
3.4 6.7
4.9 7.7
16 -
-40 °C to
+85 °C
Min Max
1.0 8.5
1.0 12
1.0 6.5
1.0 8.5
-
-
1.0 7.5
1.0 8.5
-
-
-40 °C to Unit
+125 °C
Min Max
1.0 11.0 ns
1.0 14.5 ns
1.0 7.0 ns
1.0 9.5 ns
-
- pF
1.0 8.5 ns
1.0 10.0 ns
-
- pF
[1] tpd is the same as tPLH and tPHL.
[2] Typical values are measured at VCC = 3.3 V.
[3] Typical values are measured at VCC = 5.0 V.
[4] CPD is used to determine the dynamic power dissipation PD (μW).
PD = CPD × VCC2 × fi + Σ (CL × VCC2 × fo) where:
fi = input frequency in MHz; fo = output frequency in MHz;
CL = output load capacitance in pF;
VCC = supply voltage in Volts;
N = total load switching outputs;
Σ(CL × VCC2 × fo) = sum of outputs.